ADVERTISEMENT

Mayo’s New MRI is Compact, Comfortable and Powerful

Mayo Clinic has unveiled a new compact 3T magnetic resonance imaging (MRI) scanner designed specifically to handle scans of the head and small extremities—such as wrists, feet and ankles—that represent around 45 percent of the clinical MRI volume at the clinic.

New Cryo-Coil Improves MRI Performance

A research team has developed a high-temperature superconducting cryo-coil that allows magnetic resonance imaging (MRI) scanners to produce higher resolution images or acquire images in a shorter time than when using conventional coils. The cryo-coil works by boosting the signal-to-noise ratio (SNR)—a measure of the strength of signals carrying useful...

Scientists Map Structure of Virus Linked to Childhood Asthma

The atomic structure of an elusive cold virus linked to severe asthma and respiratory infections in children has been solved by a team of researchers at the University of Wisconsin-Madison and Purdue University. The virus was among the first samples analyzed with a new cryo-electron microscopy system at Purdue designed...

LUX Experiment Ends, Dark Matter Remains Elusive

Researchers from the Large Underground Xenon (LUX) dark matter experiment have confirmed that the experiment yielded no trace of dark matter during its final 20-month run (October 2014 - May 2016), even though its sensitivity far exceeded original expectations. The announcement was made during a presentation at the International Dark...

Physicists Collide Ultracold Atoms, Observe Pauli Exclusion

Physicists from New Zealand's University of Otago have used steerable 'optical tweezers' to split minute clouds of ultracold atoms and slowly smash them together to directly observe the Pauli Exclusion, a key theoretical principle of quantum mechanics.

UK Retailer Testing LN2 Engine in Its Refrigerated Delivery Trucks

Sainsbury’s, a major UK based retailer, has become the first company in the world to introduce a refrigerated delivery truck cooled by a liquid nitrogen powered engine. The company says the engine is expected to eliminate all emissions associated with refrigeration. It will undergo a three-month trial during which time...

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

Cryogenics in Space

Peter Kittel University of California-Berkeley pkittel@cal.berkeley.edu Space Cryogenics is the application of cryogenics to space missions. These applications fall into two broad areas, supporting space science missions and supporting the space transportation infrastructure. Science applications: The atmosphere is opaque to much of the electro-magnetic spectrum. In space, the absence of...

Cryosurgery

Review of Cryosurgery Boris Rubinsky, PhD Hebrew University School of Science and Engineering Research Center for Biomedical Engineering 78b Ross Building Givat Ram, Jerusalem 91904 Israel rubinsky@cs.huji.ac.il as published in Annual Review of Biomedical Engineering, August 2000, Vol. 2, pp. 157-187. Abstract: Cryosurgery is a surgical technique that employs freezing...

Liquefied Natural Gas

Liquefied Natural Gas as it relates to the Field of Cryogenics John W. Bonn VJ Systems, LLC johnbonn@vjsystems-lic.com Today the world is looking for a cleaner fuel and Liquefied Natural Gas (LNG) plays a large part in achieving this goal. LNG in a liquid form is at -162°C (-259°F) and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...