ADVERTISEMENT

New multi-SQUID device cuts costs, improves sensitivity

Physicists in the United Kingdom have built a multi-SQUID device that can operate at 77K, the boiling point of liquid nitrogen. According to research published in Applied Physics Letters, the new device outperforms the industry standard niobium/aluminium trilayer single-SQUIDS maintained at 4.2K. "Since our SQUID arrays operate at 77K using...

Is magnetic cooling the future of cool?

Ames Laboratory scientists almost 20 years ago announced groundbreaking progress in magnetic refrigeration and yet there are still no known commercially available products that use a magnetic cooling system. Magnetic cooling exploits the magnetocaloric effect, a temperature change of a material caused by exposing it to a changing magnetic field,...

Master Bond announces new one component epoxy

Master Bond on October 13 unveiled a new single part adhesive sealant for use in a variety of applications in aerospace, electronic, optical, specialty OEM and related industries. The Master Bond Supreme 10HTF-1 offers cryogenic serviceability from 4K to +400°F and resists an array of chemicals such as water, fuels,...

New atomic absorption spectrometer helps redefine the kelvin

A team of Australian scientists has developed an atomic absorption spectrometer that provides a new way to determine Boltzmann’s constant, a number that relates the motion of an individual atom to its temperature. The research, published in Nature Communication contributes to a worldwide scientific effort to redefine the kelvin, the...

DOE announces new accelerator stewardship funding opportunities

The US Department of Energy made available an estimated $4 million in grants on October 13 with a Funding Opportunity Announcement (FOA) for research opportunities associated with its Accelerator R&D Stewardship Program. Research funded under this FOA could lead to advances is High Energy Physics (HEP), but the grants are...

ADVERTISEMENT

Mixed Refrigerant Cycles

Most cryogenic refrigeration systems, both large scale systems and cryocoolers, use helium as a working fluid. There are a number of advantages to helium, not the least of which is that helium remains a fluid down to the lowest achievable temperatures. In order to freeze helium, pressures of over 20...

Fountain Pumps and He II Phase Separators

Helium II (He II), the second liquid phase of the 4He isotope described in this column in Cold Facts Spring 2010 (http://2csa.us/he2), can be modeled as consisting of two interpenetrating fluids. One, the superfluid component, has zero viscosity and entropy and the other, the normal fluid component, has nonzero viscosity...

Turboexpanders

A vital technology in the refrigerators and liquefiers described in Cold Facts Volume 31 Number 3 is that of turboexpanders. These devices are rotating machines in which the process fluid (e.g., helium) does work against the turboexpander while moving from high pressure to a lower pressure and thus is cooled....

Magnetic Levitation

From http://www.superconductors.org. Magnetic-levitation is an application where superconductors perform extremely well. Transport vehicles such as trains can be made to “float” on strong superconducting magnets, virtually eliminating friction between the train and its tracks. Not only would conventional electromagnets waste much of the electrical energy as heat, they would have...

Superconductivity

From Superpower website. History of Superconductivity Superconductivity was discovered in 1911 by the Dutch physicist, Heike Kammerlingh Onnes when he was able to liquefy helium by cooling it to 4 Kelvin, or -452°F. This enabled him to cool other materials close to absolute zero and investigate their electrical properties. He...

Medical Applications of Cryogenics

Neutron Therapy Cryogenics is at the heart of nuclear accelerators. Accelerators such as Fermilab’s Tevatron make neutron therapy for cancer possible. From Fermilab Today 4/20/09: Fermilab currently offers neutron therapy. But staff at Fermilab designed and built the proton accelerator used by the nation’s first hospital-based treatment center to use...

Nuclear Physics

Al Zeller National Superconducting Cyclotron Lab (NSCL) at Michigan State University zeller@nscl.msu.edu Cryogenics has a long history in nuclear physics. The technology has its origins in the use of cold traps for maintaining a vacuum, which is required to prevent beam loss and for generating high voltages used in acceleration....

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks