Phase 1 installation of the MicroBooNE experiment at the Liquid Argon Test Facility at Fermi National Accelerator Laboratory has made very good progress over the summer.
Taylor-Wharton Cryogenics LCC has introduced a new generation of MicroBulk storage tanks. This new family of MicroBulk cryogenic storage vessels uses the latest cold stretch manufacturing technology with improved updated features and capabilities, addressing the efficient storage and dispensing needs of industrial, health care, laboratories and food production businesses engaged...
Gregory H. Johnson, Colonel (Ret), has been named executive director for the Center for the Advancement of Science in Space (CASIS), the nonprofit entity selected by NASA to manage the utilization of the International Space Station (ISS) US National Laboratory. Col. Johnson will assume his role on September 1, 2013.
The growth of storing and preserving biological materials in cryogenic liquid nitrogen freezers has resulted in many options and challenges in how to effectively supply these systems with the cryogenic liquid they require. Evaluating options, sizing and safety considerations is critical to determining the path a university laboratory or research...
A crowd of researchers from government labs, academia and industry gathered at Fermilab July 23-24 for the first-ever users' meeting for the Advanced Superconducting Test Accelerator, which produced its first electrons in late June. The primary goal of ASTA is to provide a home for accelerator R&D, specifically in the...
Scientists at the US Department of Energy's (DOE) Brookhaven National Laboratory and other collaborating institutions have discovered a surprising twist in the magnetic properties of high-temperature superconductors (HTS), challenging some of the leading theories. In a new study, published online in the journal Nature Materials on August 4, scientists found...
A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...
Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...
A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...
From the Fall 1999 issue of Cold Facts magazine Millennium Breakthroughs A variety of CSA members give different perspectives on the past millennium: What were the most significant breakthroughs in cryogenics during the past millennium? Prof. R.G. Scurlock, Kryos Technology, scurlock@soton.ac.uk (“Breakthrough” = way through obstacles — Oxford English Dictionary)...
Andreas Sputtek Past President Society for Cryobiology sputtek@uke.uni-hamburg.de or http://www.sputtek.de/. The word cryobiology (from the Greek words “cryo” = cold, “bios” = life, and “logos” = science) literally signifies the science of life at low temperatures. In practice, this field comprises the study of any biological material or system (e.g.,...
James E. Fesmire Cryogenics Test Laboratory NASA Kennedy Space Center james.e.fesmire@nasa.gov Introduction In today’s world, the use of cryogenics and low-temperature refrigeration is taking a more and more significant role. From the food industry, transportation, energy, and medical applications to the Space Shuttle, cryogenic liquids must be stored, handled, and...
F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...
A recent project highlighted to me that closed cycle cryogenic cooling systems use far more electrical power to reduce temperatures by a few watts than regular refrigerators. I am sure it must be something to do with the extra difficulty of removing the heat from the liquid nitrogen or similar...
I was wondering what kind of redundancy strategies are people using for their mechanical -80C freezers? I am aware of the following. Please add if you are doing something different. 1) 1 Backup freezer for every 10 freezers – Empty and maintained at -80C at all times 2) Backup C02...
I am looking for any safety guidelines for handling cryogenic vessels of nitrogen indoors and outdoors. I am especially interested in recommendations for area monitors to detect leaks, flow detection devices, etc.
Does anyone know of a method with which to reliably move components in a cryogenic environment? We are interested in moving detectors in a cryogenically cooled (2K) vacuum chamber, which is contained within a larger cryostat/isolation vacuum with thermal shields. As the desired horizontal or vertical displacement is between 10...