A new image from NASA’s Stratospheric Observatory for Infrared Astronomy (SOFIA) shows a complex distribution of interstellar dust and stars in the Orion nebula.
New evidence this week supports a theory developed five years ago at Rice University to explain the electrical properties of several classes of materials -- including unconventional superconductors -- that have long vexed physicists.
Cryogenic testing is complete for the final six primary mirror segments and a secondary mirror that will fly on NASA's James Webb Space Telescope. The milestone represents the successful culmination of a process that took years and broke new ground in manufacturing and testing large mirrors.
Two teams of physicists at the U.S. Department of Energy's Fermilab and Lawrence Berkeley National Laboratory (Berkeley Lab) have independently made the largest direct measurements of the invisible scaffolding of the universe, building maps of dark matter using new methods that, in turn, will remove key hurdles for understanding dark...
In a recent Quantum Diaries blog, Laura Fields of Fermi National Accelerator Laboratory discusses this phenomenon. The MINERvA experiment is all about trying to understand what happens when neutrinos collide with ordinary matter.
Physicist Sascha Mehlhase may have missed the actual construction of the ATLAS detector at CERN, but he found another way to experience the joy of building it – a way reminiscent of his childhood and the contents of a particularly good toy box he once had. He made the detector...
A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...
Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...
A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...
From the Fall 1999 issue of Cold Facts magazine Millennium Breakthroughs A variety of CSA members give different perspectives on the past millennium: What were the most significant breakthroughs in cryogenics during the past millennium? Prof. R.G. Scurlock, Kryos Technology, scurlock@soton.ac.uk (“Breakthrough” = way through obstacles — Oxford English Dictionary)...
Andreas Sputtek Past President Society for Cryobiology sputtek@uke.uni-hamburg.de or http://www.sputtek.de/. The word cryobiology (from the Greek words “cryo” = cold, “bios” = life, and “logos” = science) literally signifies the science of life at low temperatures. In practice, this field comprises the study of any biological material or system (e.g.,...
James E. Fesmire Cryogenics Test Laboratory NASA Kennedy Space Center james.e.fesmire@nasa.gov Introduction In today’s world, the use of cryogenics and low-temperature refrigeration is taking a more and more significant role. From the food industry, transportation, energy, and medical applications to the Space Shuttle, cryogenic liquids must be stored, handled, and...
F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...
We are looking for manufacturers of cryogenic dewars with infrared detectors (long wave). We need these dewars for repairing infrared systems (thermographic systems) and we cannot find such glass dewars. Do you know any manufacturers’ addresses?
Would you please suggest a few manufacturers that produce cryogenic regenerator lead spheres? The size we need is 0.15mm-0.2mm. I don’t have a lot of ideas for where to go to purchase them.
We are fabricating piping components for refrigeration service. These components must be leak checked at 15 bar (218 psig). We are using a gas test media that is 25% helium and experiencing difficulty on maintaining a seal on the flanged connections. Do you know anyone or any references that could...
Could anyone please help me out with the following cryogenics data: Leather — mechanical properties at 77 K or lower Nomex — thermal conductivity @ 4 to 50 K I lost the data I had some time ago and although this should be easily accessible, I can’t find any reference...