New Thermometer Measures Cryogenic Temperatures at Submicron Scales
Taking the temperature of a sample can be tricky—especially in the regimes of the very small and the very cold. The smaller the sample, the greater the influence the thermometer itself may exert on the measurement. And in the ultracold regime, even tiny amounts of heat can significantly alter the...
November 7, 2023
SpaceWrap™ is Now AstraWrap™
CSA April Newsletter SponsorHigh-performance, highly reliable, long-lasting storage tanks for transporting hydrogen & helium molecules around the globe.https://www.gardnercryo.com [Contact Jamie Luedtke for Newsletter Sponsorship] Home About Membership Login Calendar Cold Facts Buyer’s Guide News Publications Cryo Careers Resources Donate Join now Log in Cryogenic Society of America, Inc. Twitter Facebook...
November 7, 2023
Nanoparticles Show Quick and Easy Way to Target Cancer
Researchers have been exploring the use of injectable nanoparticles that can quickly home in on a microscopic tumor. It’s a novel technique that could pave the way for the early detection of small tumors that may not show up on traditional imaging technologies. In a study published in the October issue of...
November 7, 2023
Researchers Simplify Switching for Quantum Electronics
A quantum cousin of the Hall effect could open the door to energy-efficient electronics, better sensors, and more-powerful quantum computers. Researchers have now broken a key barrier to its practical application by controlling the phenomenon electrically, rather than magnetically, for the first time. The Hall effect, discovered by physicist Edwin...
November 7, 2023
ATLAS Measures Strength of the Strong Force with Record Precision
Binding together quarks into protons, neutrons and atomic nuclei is a force so strong, it’s in the name. The strong force, which is carried by gluon particles, is the strongest of all fundamental forces of nature – the others being electromagnetism, the weak force and gravity. Yet, it’s the least...
October 16, 2023
Refrigerators and Liquefiers
Two of the most common terms used in cryogenics are “refrigerator” and “liquefier.” These terms describe similar and, as will be seen, in some cases identical components. A refrigerator provides cooling (that is, absorbs heat) at cryogenic temperatures. Refrigerators typically put a working fluid (such as helium) through one of...
July 15, 2015
Air Separation
Air separation is one of the largest, as well as earliest, industrial applications of cryogenics. In this process, cryogenic temperatures are used to separate air into its constituent gases: nitrogen (78.08%), oxygen (20.95%), argon (0.93%) and carbon dioxide (0.3%). Trace gases such as krypton, neon, xenon and helium total far...
April 13, 2015
Coefficient of Performance and Figure of Merit
The coefficient of performance (COP) is used to describe the effectiveness of refrigerators, including those operating at cryogenic temperatures. The COP is defined as the amount of heat removed at the cryogenic operating temperature of the refrigerator divided by the amount of work that must be applied to remove the...
March 17, 2015
Cryogenic Treatment of Materials
F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...
April 18, 2008
Cryogenics in Space
Peter Kittel University of California-Berkeley pkittel@cal.berkeley.edu Space Cryogenics is the application of cryogenics to space missions. These applications fall into two broad areas, supporting space science missions and supporting the space transportation infrastructure. Science applications: The atmosphere is opaque to much of the electro-magnetic spectrum. In space, the absence of...
April 18, 2008
Cryosurgery
Review of Cryosurgery Boris Rubinsky, PhD Hebrew University School of Science and Engineering Research Center for Biomedical Engineering 78b Ross Building Givat Ram, Jerusalem 91904 Israel rubinsky@cs.huji.ac.il as published in Annual Review of Biomedical Engineering, August 2000, Vol. 2, pp. 157-187. Abstract: Cryosurgery is a surgical technique that employs freezing...
April 18, 2008
Liquefied Natural Gas
Liquefied Natural Gas as it relates to the Field of Cryogenics John W. Bonn VJ Systems, LLC johnbonn@vjsystems-lic.com Today the world is looking for a cleaner fuel and Liquefied Natural Gas (LNG) plays a large part in achieving this goal. LNG in a liquid form is at -162°C (-259°F) and...
April 18, 2008
An Issue of Pressure and Flow Rate in a Supply Tank
Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...
April 20, 2018
Using MLI on VJ Line Joints or Cryo Storage Tanks
When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...
April 20, 2018
Separated layers of ice over a pipe
I want to know that why there are different layers of ice over a pipe carrying a cryogenic fluid, each layer separated with clear marks / lines? What do these layers signify?
February 8, 2016
Using nitrogen as a cryogen
Is it possible to achieve -200˚C using nitrogen as a cryogen?
January 20, 2015