ADVERTISEMENT

SESAME Delivers Its First Light

Scientists at SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) recorded first monochromatic light through the XAFS/XRF spectroscopy beamline in November, signaling the start of the laboratory’s experimental program. The beamline, SESAME’s first to come on stream, delivers X-ray light that will be used to carry out...

FAST Electron Beam Achieves Milestone Energy

In November, a team at the Fermilab Accelerator Science and Technology (FAST) facility ramped up a beam of electrons to 300 million electronvolts, a double milestone event, according to the lab. For one, the beam surpassed the threshold needed to launch a new accelerator physics program at Fermi National Accelerator...

Argonne Welcomes GRETINA Back Home

A world-class gamma ray spectrometer called GRETINA has returned to Argonne National Laboratory (CSA CSM) for a second run expected to last 18 months. Scientists will use the instrument in conjunction with Argonne’s Fragment Mass Analyzer, where it will enable studies of nuclei at or near the proton drip line...

UTSW Releases First Atomic Structure From its Cryo-EM Facility

UT Southwestern Medical Center researchers have published a 3-D atomic structure of the ion channel found in mammals that is implicated in a rare, inherited neurodegenerative disease in humans. The work marks the first such structure determined using the university’s $17 million cryo-electron microscopy (cryo-EM) facility.

Novel Lenses Enable X-ray Microscopy with Record Resolution

Researchers at DESY have reported the creation of novel lenses that enable X-ray microscopy with record resolution. The new lenses consist of over 10,000 alternating layers of a new material combination—tungsten carbide and silicon carbide—that allowed the team to achieve a focus spot size with a diameter of less than...

ICC20 Accepting Abstracts for 2018 Conference

Abstract submission is now open for the 20th International Cryocooler Conference (ICC20), the premier global gathering on cryocooler technology. The meeting will feature oral and poster presentation sessions, plus CSA's Foundations of Cryocoolers short course.

ADVERTISEMENT

Refrigerators and Liquefiers

Two of the most common terms used in cryogenics are “refrigerator” and “liquefier.” These terms describe similar and, as will be seen, in some cases identical components. A refrigerator provides cooling (that is, absorbs heat) at cryogenic temperatures. Refrigerators typically put a working fluid (such as helium) through one of...

Air Separation

Air separation is one of the largest, as well as earliest, industrial applications of cryogenics. In this process, cryogenic temperatures are used to separate air into its constituent gases: nitrogen (78.08%), oxygen (20.95%), argon (0.93%) and carbon dioxide (0.3%). Trace gases such as krypton, neon, xenon and helium total far...

Coefficient of Performance and Figure of Merit

The coefficient of performance (COP) is used to describe the effectiveness of refrigerators, including those operating at cryogenic temperatures. The COP is defined as the amount of heat removed at the cryogenic operating temperature of the refrigerator divided by the amount of work that must be applied to remove the...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

Cryogenics in Space

Peter Kittel University of California-Berkeley pkittel@cal.berkeley.edu Space Cryogenics is the application of cryogenics to space missions. These applications fall into two broad areas, supporting space science missions and supporting the space transportation infrastructure. Science applications: The atmosphere is opaque to much of the electro-magnetic spectrum. In space, the absence of...

Cryosurgery

Review of Cryosurgery Boris Rubinsky, PhD Hebrew University School of Science and Engineering Research Center for Biomedical Engineering 78b Ross Building Givat Ram, Jerusalem 91904 Israel rubinsky@cs.huji.ac.il as published in Annual Review of Biomedical Engineering, August 2000, Vol. 2, pp. 157-187. Abstract: Cryosurgery is a surgical technique that employs freezing...

Liquefied Natural Gas

Liquefied Natural Gas as it relates to the Field of Cryogenics John W. Bonn VJ Systems, LLC johnbonn@vjsystems-lic.com Today the world is looking for a cleaner fuel and Liquefied Natural Gas (LNG) plays a large part in achieving this goal. LNG in a liquid form is at -162°C (-259°F) and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...