ADVERTISEMENT

The Robots of CERN

The LHC contains 120 tons of liquid helium kept at 1.9 K. And even with safety systems in place, engineers there prefer to limit underground access when the cryogenic systems are activated. Enter TIM—the Train Inspection Monorail. TIM is a chain of wagons, sensors and cameras that snake along a...

Still Cooling after All These Years

Fifteen years is a long time for any high-tech cryogenic device to continue working, but that is just what an M77 cryocooler aboard NASA's RHESSI satellite has accomplished. Designed by Sunpower, Inc. (CSA CSM), the unit's piston has cycled over 26 billion times over this period. And, as periodic oil...

Cornell Professor Takes Home 2017 Lee Osheroff Richardson Science Prize

Oxford Instruments has awarded Dr. Brad Ramshaw, assistant professor at Cornell University, its 2017 LOR Science Prize. The Lee Osheroff Richardson (LOR) Science Prize promotes and recognizes the novel work of young scientists working in the fields of low temperatures or high magnetic fields in the Americas. The trophy and...

CSA Remembers Peter Gifford 1947 – 2017

We regret to report that Peter Gifford, longtime leader of Cryomech, Inc., passed away in January 2017, surrounded by family and friends at his Syracuse home. He was 68. Gifford was a leader in the cryogenic community, a dedicated member of CSA and one of the second-generation industry leaders affectionately...

CUORE Reaches Its Operating Temperature

The Cryogenic Underground Observatory for Rare Events experiment (CUORE) reached a new milestone in late January when its detector reached its operating temperature of 10 mk. The detector has 19 towers formed from 988 Tellurium oxide crystals, and it weighs nearly 1,650 lbs. Engineers finished installing the detector into the...

ADVERTISEMENT

Mixed Refrigerant Cycles

Most cryogenic refrigeration systems, both large scale systems and cryocoolers, use helium as a working fluid. There are a number of advantages to helium, not the least of which is that helium remains a fluid down to the lowest achievable temperatures. In order to freeze helium, pressures of over 20...

Fountain Pumps and He II Phase Separators

Helium II (He II), the second liquid phase of the 4He isotope described in this column in Cold Facts Spring 2010 (http://2csa.us/he2), can be modeled as consisting of two interpenetrating fluids. One, the superfluid component, has zero viscosity and entropy and the other, the normal fluid component, has nonzero viscosity...

Turboexpanders

A vital technology in the refrigerators and liquefiers described in Cold Facts Volume 31 Number 3 is that of turboexpanders. These devices are rotating machines in which the process fluid (e.g., helium) does work against the turboexpander while moving from high pressure to a lower pressure and thus is cooled....

History of Cryogenics

From the Fall 1999 issue of Cold Facts magazine Millennium Breakthroughs A variety of CSA members give different perspectives on the past millennium: What were the most significant breakthroughs in cryogenics during the past millennium? Prof. R.G. Scurlock, Kryos Technology, scurlock@soton.ac.uk (“Breakthrough” = way through obstacles — Oxford English Dictionary)...

Cryobiology

Andreas Sputtek Past President Society for Cryobiology sputtek@uke.uni-hamburg.de or http://www.sputtek.de/. The word cryobiology (from the Greek words “cryo” = cold, “bios” = life, and “logos” = science) literally signifies the science of life at low temperatures. In practice, this field comprises the study of any biological material or system (e.g.,...

Cryogenic Insulation

James E. Fesmire Cryogenics Test Laboratory NASA Kennedy Space Center james.e.fesmire@nasa.gov Introduction In today’s world, the use of cryogenics and low-temperature refrigeration is taking a more and more significant role. From the food industry, transportation, energy, and medical applications to the Space Shuttle, cryogenic liquids must be stored, handled, and...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...