ADVERTISEMENT

The Robots of CERN

The LHC contains 120 tons of liquid helium kept at 1.9 K. And even with safety systems in place, engineers there prefer to limit underground access when the cryogenic systems are activated. Enter TIM—the Train Inspection Monorail. TIM is a chain of wagons, sensors and cameras that snake along a...

Still Cooling after All These Years

Fifteen years is a long time for any high-tech cryogenic device to continue working, but that is just what an M77 cryocooler aboard NASA's RHESSI satellite has accomplished. Designed by Sunpower, Inc. (CSA CSM), the unit's piston has cycled over 26 billion times over this period. And, as periodic oil...

Cornell Professor Takes Home 2017 Lee Osheroff Richardson Science Prize

Oxford Instruments has awarded Dr. Brad Ramshaw, assistant professor at Cornell University, its 2017 LOR Science Prize. The Lee Osheroff Richardson (LOR) Science Prize promotes and recognizes the novel work of young scientists working in the fields of low temperatures or high magnetic fields in the Americas. The trophy and...

CSA Remembers Peter Gifford 1947 – 2017

We regret to report that Peter Gifford, longtime leader of Cryomech, Inc., passed away in January 2017, surrounded by family and friends at his Syracuse home. He was 68. Gifford was a leader in the cryogenic community, a dedicated member of CSA and one of the second-generation industry leaders affectionately...

CUORE Reaches Its Operating Temperature

The Cryogenic Underground Observatory for Rare Events experiment (CUORE) reached a new milestone in late January when its detector reached its operating temperature of 10 mk. The detector has 19 towers formed from 988 Tellurium oxide crystals, and it weighs nearly 1,650 lbs. Engineers finished installing the detector into the...

ADVERTISEMENT

Cold Compressors

A common way to provide cooling below the normal boiling point of helium (4.2K) is to reduce the pressure above the bath of liquid helium, thus also reducing the bath’s equilibrium saturation temperature. For example, to produce a 1.8K bath of liquid helium, the saturation pressure has to be reduced...

Kapitza Conductance

Kapitza conductance refers to the heat transfer between a solid surface and a fluid that covers that surface. Fundamentally, it describes the inherent difficulty in transferring energy from a solid to the fluid covering the solid surface. This phenomenon was first observed by P. L. Kapitza in 1941 while studying...

Thermosyphons

A thermosyphon (or thermosiphon) is a device that transfers heat via natural convection in a fluid. The natural convection is driven by gravity with the colder, denser fluid flowing downhill and the warmer, less dense fluid flowing back up. Thus, thermosyphons connect an object to be cooled with a reservoir...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

Cryogenics in Space

Peter Kittel University of California-Berkeley pkittel@cal.berkeley.edu Space Cryogenics is the application of cryogenics to space missions. These applications fall into two broad areas, supporting space science missions and supporting the space transportation infrastructure. Science applications: The atmosphere is opaque to much of the electro-magnetic spectrum. In space, the absence of...

Cryosurgery

Review of Cryosurgery Boris Rubinsky, PhD Hebrew University School of Science and Engineering Research Center for Biomedical Engineering 78b Ross Building Givat Ram, Jerusalem 91904 Israel rubinsky@cs.huji.ac.il as published in Annual Review of Biomedical Engineering, August 2000, Vol. 2, pp. 157-187. Abstract: Cryosurgery is a surgical technique that employs freezing...

Liquefied Natural Gas

Liquefied Natural Gas as it relates to the Field of Cryogenics John W. Bonn VJ Systems, LLC johnbonn@vjsystems-lic.com Today the world is looking for a cleaner fuel and Liquefied Natural Gas (LNG) plays a large part in achieving this goal. LNG in a liquid form is at -162°C (-259°F) and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...