ADVERTISEMENT

Fermilab’s flagship accelerator sets world record

On July 8, scientists announced that the US Department of Energy's Fermi National Accelerator Laboratory (Fermilab, CSA CSM) set a world record for the most powerful high-energy particle beam for neutrino experiments: a sustained 521-kilowatt beam generated by the Main Injector particle accelerator. More than 1,000 physicists from around the...

IEEE CSC Graduate Study Fellowship winners announced

The IEEE Council on Superconductivity (CSC) Awards Committee has announced the winners of the 2015 IEEE CSC Graduate Study Fellowship. The fellowship is awarded annually to a full-time graduate student pursuing a PhD (or equivalent) degree in the area of applied superconductivity and is intended to encourage students to enter...

LCLS-II Upgrade to Enable Pioneering Research in Many Fields

Cold Facts visited Fermi National Accelerator Laboratory recently to learn more about the lab's involvement in LCLS-II, a project that will provide a major upgrade to the functionality of the existing Linac Coherent Light Source (LCLS) at the Stanford Linear Accelerator Laboratory. LCLS-II involves several scientific institutions, features cutting-edge physics...

PIP-II to Advance Intense Particle Beam Physics

With the power of Proton Improvement Plan-II, Fermi National Accelerator Laboratory is planning to construct and operate the foremost facility in the world for particle physics utilizing intense beams.

Pump Design and Operation Tips from DH Industries

Pumps and their efficiencies will increase the heat load of a closed loop cryogenic cooling system, so it is important that these pumps be as efficient as possible to minimize cost and supply use. Francesco Dioguardi, Martijn Donkers and Harrie Vermeulen of DH Industries provide pump design and operation tips...

ADVERTISEMENT

Joule-Thomson Effect

The Joule-Thomson (JT) effect is a thermodynamic process that occurs when a fluid expands from high pressure to low pressure at constant enthalpy (an isenthalpic process). Such a process can be approximated in the real world by expanding a fluid from high pressure to low pressure across a valve. Under...

Current Leads

One of the challenges of using superconducting magnets is the connection of the magnet to a room temperature power supply. This is accomplished via current leads. The trick is that current leads should ideally have a low heat leak, since they connect room temperature to cryogenic temperature, while at the...

Multilayer Insulation

Multilayer insulation (also referred to as superinsulation) is a key component in the reduction of heat leak to cryogenic systems due to thermal radiation. MLI consists of a series of uncooled reflective surfaces placed in the vacuum space between two surfaces, one warmer than the other. Generally speaking, for ideal...

Magnetic Levitation

From http://www.superconductors.org. Magnetic-levitation is an application where superconductors perform extremely well. Transport vehicles such as trains can be made to “float” on strong superconducting magnets, virtually eliminating friction between the train and its tracks. Not only would conventional electromagnets waste much of the electrical energy as heat, they would have...

Superconductivity

From Superpower website. History of Superconductivity Superconductivity was discovered in 1911 by the Dutch physicist, Heike Kammerlingh Onnes when he was able to liquefy helium by cooling it to 4 Kelvin, or -452°F. This enabled him to cool other materials close to absolute zero and investigate their electrical properties. He...

Medical Applications of Cryogenics

Neutron Therapy Cryogenics is at the heart of nuclear accelerators. Accelerators such as Fermilab’s Tevatron make neutron therapy for cancer possible. From Fermilab Today 4/20/09: Fermilab currently offers neutron therapy. But staff at Fermilab designed and built the proton accelerator used by the nation’s first hospital-based treatment center to use...

Nuclear Physics

Al Zeller National Superconducting Cyclotron Lab (NSCL) at Michigan State University zeller@nscl.msu.edu Cryogenics has a long history in nuclear physics. The technology has its origins in the use of cold traps for maintaining a vacuum, which is required to prevent beam loss and for generating high voltages used in acceleration....

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...