ADVERTISEMENT

Manufacturer of liquid pump for use at 170 K

We’re in need of a liquid pump for use at 170 K in our refrigerator to pump Paratherm cryogenic heat transfer fluid. Can anyone suggest a manufacturer? Our flow rate is 16 liters/minute, and a head of 10 m. The specific gravity of the fluid is 0.85 and the viscosity...

Question about configuration of an 80 K helium circuit

I have a question about a possible configuration of an 80 K helium circuit from our cryogenic plant. A helium flow at 80 K and 18 bar is needed at the customer’s inlet. In order to decouple the refrigerator from the customer, I thought to propose the following solution: –...

Properties for steel 1.4037 at 77 K

Does anyone know the properties at 77 K for steel 1.4037 ( X 65 Cr 13) which is used for ball bearings? We are looking for values of thermal expansion.

Pier Oddone to step down as Fermilab director

Fermilab Director Pier Oddone has decided to retire after eight years at the helm of America’s leading particle physics laboratory. Oddone will continue to serve as Fermilab director until July 1, 2013, while a committee appointed by the FRA Board Chairman conducts an international search for his successor.

Researchers’ insight on ‘pseudogap’ an important advance

More than two decades after scientists discovered a new type of copper-based high-temperature superconductor — energy-efficient material that can carry electricity without waste — Harvard physicists say they have unlocked the chemical secret that controls its “fool’s gold” phase, which mimics, but doesn’t have all the advantageous properties of, superconductivity.

ADVERTISEMENT

Liquid Hydrogen

Hydrogen becomes a liquid at 20K and 1 bar. Liquid hydrogen (LH2) is an important substance in industry, transportation and research. Industrial uses of hydrogen include applications in the electronics, glass, chemical and metal processing fields. In these applications, the hydrogen is generally used as a room temperature gas but...

Superconducting Radiofrequency Cavities

Superconducting radio frequency (SRF) cavities represent an important application of cryogenics and superconductivity. SRF cavities are a technology for accelerating charged particle beams via the transfer of radiofrequency (RF) energy to the beams via resonant structures. As such, they are frequently found in large particle accelerators used for scientific research....

Thermal Radiation Shields

Actively cooled thermal radiation shields are a common feature of cryostats whose lowest temperature is less than 77K. These shields, which typically operate at temperatures between that of LN2 and 40K, block thermal radiation from higher temperatures from reaching lower temperature cryogenic components or fluids. Since the heat radiated from...

History of Cryogenics

From the Fall 1999 issue of Cold Facts magazine Millennium Breakthroughs A variety of CSA members give different perspectives on the past millennium: What were the most significant breakthroughs in cryogenics during the past millennium? Prof. R.G. Scurlock, Kryos Technology, scurlock@soton.ac.uk (“Breakthrough” = way through obstacles — Oxford English Dictionary)...

Cryobiology

Andreas Sputtek Past President Society for Cryobiology sputtek@uke.uni-hamburg.de or http://www.sputtek.de/. The word cryobiology (from the Greek words “cryo” = cold, “bios” = life, and “logos” = science) literally signifies the science of life at low temperatures. In practice, this field comprises the study of any biological material or system (e.g.,...

Cryogenic Insulation

James E. Fesmire Cryogenics Test Laboratory NASA Kennedy Space Center james.e.fesmire@nasa.gov Introduction In today’s world, the use of cryogenics and low-temperature refrigeration is taking a more and more significant role. From the food industry, transportation, energy, and medical applications to the Space Shuttle, cryogenic liquids must be stored, handled, and...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...