ADVERTISEMENT

Cryoforce Spectroscopy Reveals DNA Mechanical Properties

Physicists from the University of Basel have developed a low temperature method to examine the elasticity and binding properties of DNA molecules. The process utilized cryoforce spectroscopy and computer simulations, a combination that revealed DNA molecules behaving like a chain of small coil springs.

New Theory Sends Kelvin Temperature Below Current Low

A recent collaboration of researchers has shown that it is possible, in principle, to measure temperatures below a billionth of a kelvin without significantly disturbing the Bose-Einstein condensate used in the study.

Pre-excavation Work Begins on LBNF/DUNE

An international project to build the largest physics experiment ever constructed in the United States took a major step forward as a new phase of work began at the Sanford Underground Research Facility in South Dakota. When completed entirely, a beam of neutrinos will be sent from Fermi National Accelerator...

Concept Design Released for CERN’s Future Circular Collider

Scientists have for some time been planning the post-LHC world at CERN, especially the Future Circular Collider collaboration. FCC members recently discussed and published options for the future large circular collider and more, mixing advancements in physics together with cost and technical challenges.

ADVERTISEMENT

Dilution Refrigerators

Dilution refrigerators are a common technique for reaching temperatures below 1K, particularly where continuous cooling at these temperatures is required. Helium exists in two stable isotopes: 4He and 3He. Naturally occurring 3He is extremely rare, constituting less than 1 part per million of helium gas. However, 3He can be manufactured,...

Oxygen Deficiency Hazards

Oxygen Deficiency Hazards (ODH) are a significant safety issue in cryogenic facilities. ODH occurs when inert gases such as nitrogen, helium or argon displace room air and thus lower the percentage of oxygen in the space below that required for human life. OSHA defines an area as oxygen deficient if...

Kelvin Temperature Scale

The Kelvin temperature scale is the principal temperature scale used in cryogenics and science. The kelvin is also one of the seven base units in the Système International d’Unités (SI) and is the unit of thermodynamic temperature. Thermodynamic temperature is a fundamental physical quantity (like mass, length or electrical current)...

Magnetic Levitation

From http://www.superconductors.org. Magnetic-levitation is an application where superconductors perform extremely well. Transport vehicles such as trains can be made to “float” on strong superconducting magnets, virtually eliminating friction between the train and its tracks. Not only would conventional electromagnets waste much of the electrical energy as heat, they would have...

Superconductivity

From Superpower website. History of Superconductivity Superconductivity was discovered in 1911 by the Dutch physicist, Heike Kammerlingh Onnes when he was able to liquefy helium by cooling it to 4 Kelvin, or -452°F. This enabled him to cool other materials close to absolute zero and investigate their electrical properties. He...

Medical Applications of Cryogenics

Neutron Therapy Cryogenics is at the heart of nuclear accelerators. Accelerators such as Fermilab’s Tevatron make neutron therapy for cancer possible. From Fermilab Today 4/20/09: Fermilab currently offers neutron therapy. But staff at Fermilab designed and built the proton accelerator used by the nation’s first hospital-based treatment center to use...

Nuclear Physics

Al Zeller National Superconducting Cyclotron Lab (NSCL) at Michigan State University zeller@nscl.msu.edu Cryogenics has a long history in nuclear physics. The technology has its origins in the use of cold traps for maintaining a vacuum, which is required to prevent beam loss and for generating high voltages used in acceleration....

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...