ADVERTISEMENT

Chart Acquires Skaff Cryogenics

Chart Industries, Inc. announced its acquisition of Skaff Cryogenics and Cryo-Lease, LLC in early January. The acquisition, according to Chart, expands the company's direct regional presence for service and aftermarket support in the Northeast United States.

Dippin’ Dots Launches Cryogenic Company

Dippin' Dots, known for its popular flash frozen beaded ice cream, welcomed the new year with the launch of Dippin' Dots Cryogenics, LLC, an offshoot designed to leverage its intellectual property in cryogenic processes and machinery.

Common Oxygen Catalyst Soaks Up Hydrogen Too

Scientists at Oak Ridge National Laboratory (CSA CSM) have discovered that an oxygen sponge used in vehicle exhaust systems to soak up oxygen from air and store it for later use may also be a hydrogen sponge. The finding, according to the researchers, may pave the way for the design...

SESAME Delivers Its First Light

Scientists at SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) recorded first monochromatic light through the XAFS/XRF spectroscopy beamline in November, signaling the start of the laboratory’s experimental program. The beamline, SESAME’s first to come on stream, delivers X-ray light that will be used to carry out...

FAST Electron Beam Achieves Milestone Energy

In November, a team at the Fermilab Accelerator Science and Technology (FAST) facility ramped up a beam of electrons to 300 million electronvolts, a double milestone event, according to the lab. For one, the beam surpassed the threshold needed to launch a new accelerator physics program at Fermi National Accelerator...

Argonne Welcomes GRETINA Back Home

A world-class gamma ray spectrometer called GRETINA has returned to Argonne National Laboratory (CSA CSM) for a second run expected to last 18 months. Scientists will use the instrument in conjunction with Argonne’s Fragment Mass Analyzer, where it will enable studies of nuclei at or near the proton drip line...

ADVERTISEMENT

Helium II

Helium II (He II) refers to the second liquid phase of the most abundant helium isotope (4He). Helium II is also referred to as superfluid helium. Helium II occurs once the temperature of the liquid helium drops below 2.17K. The phase transition between the first liquid phase of Helium (referred...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

Seeking recommendations for commercial sensors

I would like to measure vibrations in small LHe cryostats. Could anybody recommend commercial sensors which would be suitable for the purpose? I am interested in the frequency range between 1Hz and a couple of KHz, with particular attention to the low frequency side.

Estimating cost of carbon steel, pure helium storage tanks

In order to perform an indicative cost assessment of our helium cryogenic plant (still in the design phase), I need an estimation of the cost of carbon steel room temperature pure helium storage tanks. The storage pressure is 20 bar. Can anyone give me suggestions about how to estimate the...

Supplier of pressure sensor that works down to 4.2 K

In an actual experiment we would like to measure the static pressure in a cryostat in the range between one and four bar. Therefore we are looking for some (more or less) cheap pressure sensors that work in liquid helium in the pressure range up to five bar. Unfortunately all...

Looking for reference/textbook suggestions

Can you suggest some reference textbooks for practical thermodynamics applications in cryogenic fields? I need textbooks with cryogenics calculations and examples, dimensioning procedures, second principle applications in cryogenics, heat load calculations, cryogenic pump application, etc. Do such books exist? Does any similar source of information exist?