ADVERTISEMENT

After 50 Years of ASC and Magnet Conductors, What’s Next?

Past and present superconducting magnet technology suggests that cheap, strong, available-by-the-ton Nb-Ti alloy conductors will always be used unless it’s absolutely necessary to use another superconducting material. In this decade “absolutely necessary” has taken on a clearer definition, thanks to ITER, the upgrade of LHC, 1 GHz NMR magnets, the...

Laser Powered Cryocooling Drops to 91 K

Over the last couple of decades researchers around the world have been working on optical refrigeration, a new solid-state cooling scheme based on light-matter interactions, and a team of researchers from the University of New Mexico (UNM) and ThermoDynamic Films, LLC (TDF) is currently working to harness the physics of...

Testing JWST’s MIRI Cooler Compressor Assembly

The James Webb Space Telescope’s (JWST) Mid InfraRed Instrument (MIRI) cooler subsystem features a closed cycle helium Joule-Thomson (JT) cryocooler pre-cooled by a three-stage pulse tube cryocooler. In this paper, researchers from Northrop Grumman discuss tests conducted on the CCA, a flight model sub-assembly that compresses and precools MIRI's helium...

Cryogenic System to Cool Malaysian Data Center

An international consortium has announced plans to construct a green data center that features liquid submersion cooling at a location in Malaysia's Klang Valley. The project aims to increase the sustainability of data centers by changing the way facilities are cooled, therein reducing energy consumption by up to 50 percent,...

Fine-Tuned Cryogenic Clock Improves Computing Capabilities

Researchers from the University of Adelaide in South Australia have enhanced the cryogenic sapphire clock to achieve near attosecond capability. Also known as a microwave oscillator, the clock features a five cm cylinder-shaped crystal cooled to -269°C.

New Graphene Hybrid Exceeds DOE Goal for Hydrogen Storage

Layers of graphene separated by nanotube pillars of boron nitride may be a suitable material to store hydrogen fuel in cars, according to a new computational study from Rice University published in the journal Langmuir. The material held 14.77 percent of its weight in hydrogen at -321°F, exceeding both current...

ADVERTISEMENT

Helium II

Helium II (He II) refers to the second liquid phase of the most abundant helium isotope (4He). Helium II is also referred to as superfluid helium. Helium II occurs once the temperature of the liquid helium drops below 2.17K. The phase transition between the first liquid phase of Helium (referred...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

Assistance with resolving a sealing problem?

We are fabricating piping components for refrigeration service. These components must be leak checked at 15 bar (218 psig). We are using a gas test media that is 25% helium and experiencing difficulty on maintaining a seal on the flanged connections. Do you know anyone or any references that could...

Cryogenic data on leather and nomex

Could anyone please help me out with the following cryogenics data: Leather — mechanical properties at 77 K or lower Nomex — thermal conductivity @ 4 to 50 K I lost the data I had some time ago and although this should be easily accessible, I can’t find any reference...