ADVERTISEMENT

Improving the Efficiency of Helium Transfer Tubes

One must, on a daily basis, transfer liquefied gases, most notably helium from large static tanks or dewars to smaller transportable vessels. This process can become costly due to the losses sustained during transfer, which must be compensated for by reliquefying helium, requiring between 2 and 5 kW per liquid...

MiniCLEAN detector begins search for dark matter

Researchers at Pacific Northwest National Laboratory, after eight years of designing and building, have begun commissioning and cooling the MiniCLEAN detector, a small experiment with the big goal of detecting dark matter. CLEAN stands for Cryogenic Low-Energy Astrophysics with Nobles. Scientists will use the detector to search for weakly interacting...

Air Liquide expands its business in Turkey

Air Liquide advanced Technologies expanded its foothold in Turkey on September 15 with the acquisition of Messer Aligaz Sanayi Gazlari, a subsidiary of industrial gas company Messer Group GmbH. Messer Aligaz provides industrial, medical and specialty gases to a range of industries in Turkey. The company owns and operates an...

Researchers observe dynamic Mott transition in superconductors

An international team of researchers, including the MESA+ Institute for Nanotechnology at the University of Twente in The Netherlands and the US Department of Energy’s Argonne National Laboratory (CSA CSM), has announced the first observation of a dynamic Mott transition in a superconductor. The discovery experimentally connects the worlds of...

FDA accepts BioCision’s ThawSTAR master file

The US Food and Drug Administration (FDA) this month accepted the Device Master File (MAF) submission for BioCision's ThawSTAR automated cell thawing system. The ThawSTAR MAF encompasses information pertaining to the specifications, materials and quality and manufacturing processes used in producing the ThawSTAR system.

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

Cryogenics in Space

Peter Kittel University of California-Berkeley pkittel@cal.berkeley.edu Space Cryogenics is the application of cryogenics to space missions. These applications fall into two broad areas, supporting space science missions and supporting the space transportation infrastructure. Science applications: The atmosphere is opaque to much of the electro-magnetic spectrum. In space, the absence of...

Cryosurgery

Review of Cryosurgery Boris Rubinsky, PhD Hebrew University School of Science and Engineering Research Center for Biomedical Engineering 78b Ross Building Givat Ram, Jerusalem 91904 Israel rubinsky@cs.huji.ac.il as published in Annual Review of Biomedical Engineering, August 2000, Vol. 2, pp. 157-187. Abstract: Cryosurgery is a surgical technique that employs freezing...

Liquefied Natural Gas

Liquefied Natural Gas as it relates to the Field of Cryogenics John W. Bonn VJ Systems, LLC johnbonn@vjsystems-lic.com Today the world is looking for a cleaner fuel and Liquefied Natural Gas (LNG) plays a large part in achieving this goal. LNG in a liquid form is at -162°C (-259°F) and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...