ADVERTISEMENT

Balancing the Cryopreservation Equation

BioCision executives Dr. Maria Thompson, Dr. Eric Kunkel and Dr. Rolf Ehrhardt discuss the thawing arm of the "cryopreservation equation" and the need to strictly control temperature throughout the process.

SuperPower expands Quick Ship inventory

New segments have been added to SuperPower's Quick Ship inventory. The program enables the company to ship wire to clients in as little as 1-2 business days upon acceptance of a purchase order or pre-payment.

Neutrinos can deliver both full-on hits and “glancing blows”

In what they call a “weird little corner” of the already weird world of neutrinos, physicists have found evidence that neutrinos might be involved in a surprising reaction: interacting with a nucleus and leaving it basically untouched, inflicting no more than a glancing blow.

Accelerator-powered carbon dating

Accelerator mass spectrometry, an accelerator-driven form of carbon dating that requires only a tiny sample of the material, is advancing everything from archaeology to personalized medicine.

First LHC magnets prepped for restart

One-eighth of the Large Hadron Collider (LHC) dipole magnets have reached the energy they'll need to operate in 2015. Engineers at CERN powered 154 superconducting magnets to a current of around 11,000 amps. This is about 1,000 times greater than an average household appliance and is required to make the...

Save the Date for the 2015 Space Cryogenics Workshop

NASA Glenn Research Center announces the 2015 Space Cryogenics Workshop (SCW), a division of the Cryogenic Society of America. All aspects of space cryogenics will be represented, with an emphasis on work related to previous missions as well as future research.

ADVERTISEMENT

Stability

Stability refers to the ability of a device employing superconductors to remain in its superconducting state after part of the superconductor transitions back to its normal conducting state due to a disturbance. While the concept can apply to many superconducting devices—transmission lines, generators, motors, etc.—it is most commonly considered in...

Cable-in-Conduit Conductors

Cable-in-Conduit Conductors (CICC) are a common form of superconducting cable used in large-scale applications. There are several varieties of CICCs, but they all consist of many small, stabilized superconducting wires contained within a conduit through which a coolant (typically supercritical He II) flows. Figure 1 shows the cross section of...

Bayonet Coupling

A bayonet coupling is a demountable joint that allows for quick and easy connection and disconnection of cryogenic components, including transfer lines, cryostats, liquefiers and refrigerators. Bayonets provide a number of advantages, chief among them the ability to connect and disconnect the bayonets while components they connect are still at...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

Assistance with resolving a sealing problem?

We are fabricating piping components for refrigeration service. These components must be leak checked at 15 bar (218 psig). We are using a gas test media that is 25% helium and experiencing difficulty on maintaining a seal on the flanged connections. Do you know anyone or any references that could...

Cryogenic data on leather and nomex

Could anyone please help me out with the following cryogenics data: Leather — mechanical properties at 77 K or lower Nomex — thermal conductivity @ 4 to 50 K I lost the data I had some time ago and although this should be easily accessible, I can’t find any reference...