ADVERTISEMENT

Lake Shore issues new model CRX-VF probe station specifications

Lake Shore Cryotronics, a CSA Corporate Sustaining Member, has introduced updated specifications for its Model CRX-VF cryogenic probe station, which features increased maximum magnetic field, improved magnetic field at elevated sample temperatures and improved vacuum performance.

Scientists discover new phi-Josephson junction for use in cryoelectronics

Scientists from the University of Tübingen, Germany, working with colleagues from Tel Aviv University and the University of Kiel, Germany, have proposed [1] and experimentally demonstrated [2] a new type of superconducting element – named the phi-Josephson (?-Josephson) junction. Implemented in cryogenic devices, this element will make superconducting electronic circuits...

Dr. Joel Ullom receives CSA’s Roger W. Boom Award

Dr. Joel Ullom, 2012 CSA Roger W. Boom awardee, is the NIST Project Leader for superconducting calorimeter development and has worked in the fields of low temperature sensors, low temperature electronics and cryogenic systems since 1994.

ADVERTISEMENT

Cold Compressors

A common way to provide cooling below the normal boiling point of helium (4.2K) is to reduce the pressure above the bath of liquid helium, thus also reducing the bath’s equilibrium saturation temperature. For example, to produce a 1.8K bath of liquid helium, the saturation pressure has to be reduced...

Kapitza Conductance

Kapitza conductance refers to the heat transfer between a solid surface and a fluid that covers that surface. Fundamentally, it describes the inherent difficulty in transferring energy from a solid to the fluid covering the solid surface. This phenomenon was first observed by P. L. Kapitza in 1941 while studying...

Thermosyphons

A thermosyphon (or thermosiphon) is a device that transfers heat via natural convection in a fluid. The natural convection is driven by gravity with the colder, denser fluid flowing downhill and the warmer, less dense fluid flowing back up. Thus, thermosyphons connect an object to be cooled with a reservoir...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Wind Tunnels

Dr. Robert Kilgore The development of the cryogenic wind tunnel is one of many significant breakthroughs in both cryogenics and wind-tunnel technology made during the past millennium. Interest in the development of high-speed commercial and military aircraft resulted in a review of problems of flow simulation in transonic wind tunnels...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...