ADVERTISEMENT

Refilling process of a helium cryogenic plant

I’m trying to collect some information about the refilling process of a helium cryogenic plant. Due to the physiologic losses I expect to have to foreseen a periodic refilling of helium. Our plant will be characterized by a refrigerator/liquefactor. A control cryostat with 4.5 K LHe coming from the liquefactor...

What's the best gas to use for pulse GMAW?

I have a 78″ ID vessel, 3/8″ thick shells, ½” heads, from SA-240-304L, which will have an ASME U-Stamp and I am planning on sub-arcing the seams and using pulse GMAW (ER308L for both) for the nozzles. I am comfortable with the SAW, but I am wondering about the best...

Manufacturer of liquid pump for use at 170 K

We’re in need of a liquid pump for use at 170 K in our refrigerator to pump Paratherm cryogenic heat transfer fluid. Can anyone suggest a manufacturer? Our flow rate is 16 liters/minute, and a head of 10 m. The specific gravity of the fluid is 0.85 and the viscosity...

Question about configuration of an 80 K helium circuit

I have a question about a possible configuration of an 80 K helium circuit from our cryogenic plant. A helium flow at 80 K and 18 bar is needed at the customer’s inlet. In order to decouple the refrigerator from the customer, I thought to propose the following solution: –...

Properties for steel 1.4037 at 77 K

Does anyone know the properties at 77 K for steel 1.4037 ( X 65 Cr 13) which is used for ball bearings? We are looking for values of thermal expansion.

ADVERTISEMENT

Space Cryogenics

Space cryogenics is, somewhat obviously, the application of cryogenics to space exploration and science. The use of cryogenics in space optimizes the launching of vehicles, provides power and life support to spacecraft and is critical for many scientific observations.Space cryogenics has a number of challenges and has driven both pure...

Exergy

The science of thermodynamics plays a major role in cryogenics. It underlies the various refrigeration cycles, from Carnot to Brayton (Cold Facts Vol. 32 No. 2) and Joule-Thomson, is a fundamental part of the definition of terms such as coefficient of performance (Cold Facts Vol. 31 No. 1) and even...

Cryogenic Treatment

Cryogenic treatment is the process of cooling materials to cryogenic temperatures temporarily to improve their material properties at room temperature. This is distinct from cooling materials down to cryogenic temperatures to take advantage of phenomena such as superconductivity that only occur at cryogenic temperatures. Cryogenic treatment, sometimes also referred to...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

Assistance with resolving a sealing problem?

We are fabricating piping components for refrigeration service. These components must be leak checked at 15 bar (218 psig). We are using a gas test media that is 25% helium and experiencing difficulty on maintaining a seal on the flanged connections. Do you know anyone or any references that could...

Cryogenic data on leather and nomex

Could anyone please help me out with the following cryogenics data: Leather — mechanical properties at 77 K or lower Nomex — thermal conductivity @ 4 to 50 K I lost the data I had some time ago and although this should be easily accessible, I can’t find any reference...