Does anyone know the properties at 77 K for steel 1.4037 ( X 65 Cr 13) which is used for ball bearings? We are looking for values of thermal expansion.
NASA's Curiosity rover has shipped back to Earth high-resolution color images of its surroundings on Mars, sharpening our views of an intriguing channel, layered buttes and a layer of cobbles and pebbles embedded in a finer matrix of material.
Fermilab Director Pier Oddone has decided to retire after eight years at the helm of America’s leading particle physics laboratory. Oddone will continue to serve as Fermilab director until July 1, 2013, while a committee appointed by the FRA Board Chairman conducts an international search for his successor.
More than two decades after scientists discovered a new type of copper-based high-temperature superconductor — energy-efficient material that can carry electricity without waste — Harvard physicists say they have unlocked the chemical secret that controls its “fool’s gold” phase, which mimics, but doesn’t have all the advantageous properties of, superconductivity.
A decision by the National Science Board (NSB) to award a five-year renewal grant to the National High Magnetic Field Laboratory (MagLab) will enable Florida and New Mexico to continue as research meccas for leading physicists, chemists, biologists and engineers from around the world.
The National Institutes of Health (NIH) has awarded $1 million dollars to purchase new precision detector technology for the US Department of Energy’s (DOE) Brookhaven National Laboratory.
A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...
Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...
A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...
From http://www.superconductors.org. Magnetic-levitation is an application where superconductors perform extremely well. Transport vehicles such as trains can be made to “float” on strong superconducting magnets, virtually eliminating friction between the train and its tracks. Not only would conventional electromagnets waste much of the electrical energy as heat, they would have...
From Superpower website. History of Superconductivity Superconductivity was discovered in 1911 by the Dutch physicist, Heike Kammerlingh Onnes when he was able to liquefy helium by cooling it to 4 Kelvin, or -452°F. This enabled him to cool other materials close to absolute zero and investigate their electrical properties. He...
Neutron Therapy Cryogenics is at the heart of nuclear accelerators. Accelerators such as Fermilab’s Tevatron make neutron therapy for cancer possible. From Fermilab Today 4/20/09: Fermilab currently offers neutron therapy. But staff at Fermilab designed and built the proton accelerator used by the nation’s first hospital-based treatment center to use...
Al Zeller National Superconducting Cyclotron Lab (NSCL) at Michigan State University zeller@nscl.msu.edu Cryogenics has a long history in nuclear physics. The technology has its origins in the use of cold traps for maintaining a vacuum, which is required to prevent beam loss and for generating high voltages used in acceleration....
A recent project highlighted to me that closed cycle cryogenic cooling systems use far more electrical power to reduce temperatures by a few watts than regular refrigerators. I am sure it must be something to do with the extra difficulty of removing the heat from the liquid nitrogen or similar...
I was wondering what kind of redundancy strategies are people using for their mechanical -80C freezers? I am aware of the following. Please add if you are doing something different. 1) 1 Backup freezer for every 10 freezers – Empty and maintained at -80C at all times 2) Backup C02...
I am looking for any safety guidelines for handling cryogenic vessels of nitrogen indoors and outdoors. I am especially interested in recommendations for area monitors to detect leaks, flow detection devices, etc.
Does anyone know of a method with which to reliably move components in a cryogenic environment? We are interested in moving detectors in a cryogenically cooled (2K) vacuum chamber, which is contained within a larger cryostat/isolation vacuum with thermal shields. As the desired horizontal or vertical displacement is between 10...