Liquid Helium Ballast Refrigeration

The Need for Vibration-Free Cryogenics The measurement of local gravitational fields requires continuous, high precision and extremely stable measurements. In 1968, the development of the superconducting gravity meter (SG)[1] vastly improved the state of the art. In contrast to mechanical quartz or metal springs, SGs use a superconducting sphere levitated in...

Qubit Measurement Systems Right Out of the Box?

Necessity of mK-Cryogenics-During the past years, advances in both lithography and millikelvin cryogenics have supported and enabled vast improvement in the sophistication of experimental research on electrical circuits that display uniquely quantum mechanical behavior. It comes as no surprise that dilution refrigerator measurement systems have moved beyond basic physics research...

The Development of an AMRR for Sub-Kelvin Cooling of Space Science Instrumentation – ICC21 Best Student Paper Award Recipient

Introduction-Cryogenic detectors have higher sensitivity and better energy resolution than alternative sensors, making them an attractive option for space exploration and essential for observing low energy photons in the near- or far-IR, X-ray and submillimeter ranges.[1] Since NASA’s first cryogenic missions in the early 1980s, increasingly complex space detectors have...

The Next Generation in Cryogenics and Superconductivity

CSA’s annual Young Professionals introduces outstanding engineers, scientists, and technicians (under 40) who are making fascinating contributions to the cryogenics and superconductivity industries. Debuted in the summer of 2006, this spotlight shines on future leaders who show the promise of making a difference in their fields.  We are proud to...

New Green Storage System Offers Renewable Energy On-Demand

Back to the Future movie fans may remember the term “flux capacitor” as a fictional device that allows for time travel. That device still doesn’t exist, but a University of Central Florida storage technology does use a different type of flux capacitor developed by NASA. While trying to find a way...

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Wind Tunnels

Dr. Robert Kilgore The development of the cryogenic wind tunnel is one of many significant breakthroughs in both cryogenics and wind-tunnel technology made during the past millennium. Interest in the development of high-speed commercial and military aircraft resulted in a review of problems of flow simulation in transonic wind tunnels...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...