ADVERTISEMENT

Meet Our New Board Members

As the Cryogenic Society of America moves into an exciting era of innovation and exploration, we’re thrilled to introduce the talented professionals who will help guide our organization forward. This year’s new board members bring a wealth of expertise from diverse sectors within the field, as well as a shared...

CoolCAD Electronics Pioneers Precision in Cryogenic Testing and Modeling

CoolCAD Electronics is a leading provider of electrical test services (current-voltage, capacitance-voltage, noise, transients, etc.) and compact modeling (SPICE) for companies and agencies fabricating and/or designing electronics for low temperature operation. CoolCAD Electronics is a leading-edge company specializing in cryogenic electronics design, testing, and characterization of semiconductor devices operating at...

Quantum Computing With a Revolutionary Superconducting Processor

  Researchers at the Cleland Lab, part of the University of Chicago’s Pritzker School of Molecular Engineering (PME), have unveiled a groundbreaking design for superconducting quantum processors. This new architecture features a modular router that breaks free from the traditional two-dimensional grid constraints, enhancing qubit connectivity and scalability. The advancement...

Helium Conservation by Diffusion Limited Purging of Liquid Hydrogen Tanks

The NASA Engineering and Safety Center (NESC) has developed an analytical model that predicts diffusion between two gases during piston purging of liquid hydrogen (LH2) tanks. This model helps explain dramatic helium savings seen in a recent Kennedy Space Center (KSC) purge, shows that undesired turbulent mixing occurred in Space...

Advanced Cooling Secures $1M Cryogenic Cold Wall Order

Thermal management solutions provider Advanced Cooling Technologies has received a $1 million order from Hamilton Storage to support its biological sample storage freezers. The order includes cryogenic cold walls integral to Hamilton Storage’s ongoing cold plate programme, which ensures consistent temperatures for sensitive biological specimens. Ensuring Sample Integrity Hamilton Storage...

Astoriom Opens New State-of-the-Art Cryogenic Storage Suite in Waterford

Astoriom, a global leader in life sciences R&D sample stability and biorepository storage, has unveiled a cutting-edge cryogenic storage suite at its Tramore facility in County Waterford. This new development brings unparalleled capabilities for biological sample storage to Ireland. Gerald Hurley, CEO of the Waterford Chamber of Commerce, joined Astoriom’s...

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Wind Tunnels

Dr. Robert Kilgore The development of the cryogenic wind tunnel is one of many significant breakthroughs in both cryogenics and wind-tunnel technology made during the past millennium. Interest in the development of high-speed commercial and military aircraft resulted in a review of problems of flow simulation in transonic wind tunnels...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...