ADVERTISEMENT

More than 15,000 attend Goddard Open House

NASA’s Goddard Space Flight Center in Greenbelt MD hosted more than 15,000 visitors under gray but rain-free skies on May 14. The Explore@NASA Goddard event was the center’s first open house since 2008, according to Robert Garner of the Center.

Berkeley Lab Researcher Wins DOE Early Career Award

Among the 65 Early Career Research Program award recipients announced last week by DOE’s Office of Science is Paolo Ferracin of the Superconducting Magnet Group in the Accelerator and Fusion Research Division at Lawrence Berkeley Laboratory.

LHC sets world record beam intensity

The CERN Large Hadron Collider on April 22 set a new world record for beam intensity at a hadron collider when it collided beams with a luminosity of 4.67 x 1032cm-2s-1.

James Webb mirror segments cryogenically tested at Marshall SFC

The first six of 18 segments that will form NASA's James Webb Space Telescope's primary mirror for space observations have begun final round-the-clock cryogenic testing at the X-ray and Cryogenic Facility at NASA's Marshall Space Flight Center, Huntsville AL.

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Seeking recommendations for commercial sensors

I would like to measure vibrations in small LHe cryostats. Could anybody recommend commercial sensors which would be suitable for the purpose? I am interested in the frequency range between 1Hz and a couple of KHz, with particular attention to the low frequency side.

Estimating cost of carbon steel, pure helium storage tanks

In order to perform an indicative cost assessment of our helium cryogenic plant (still in the design phase), I need an estimation of the cost of carbon steel room temperature pure helium storage tanks. The storage pressure is 20 bar. Can anyone give me suggestions about how to estimate the...

Supplier of pressure sensor that works down to 4.2 K

In an actual experiment we would like to measure the static pressure in a cryostat in the range between one and four bar. Therefore we are looking for some (more or less) cheap pressure sensors that work in liquid helium in the pressure range up to five bar. Unfortunately all...

Looking for reference/textbook suggestions

Can you suggest some reference textbooks for practical thermodynamics applications in cryogenic fields? I need textbooks with cryogenics calculations and examples, dimensioning procedures, second principle applications in cryogenics, heat load calculations, cryogenic pump application, etc. Do such books exist? Does any similar source of information exist?