ADVERTISEMENT

Advancing Spin Qubit Technology With Cryogenic Probing

In a recent article published in Nature, researchers developed a 300-mm cryogenic probing process to obtain high-volume data on spin qubit devices across full wafers. They optimized an industry-compatible process to fabricate spin qubit devices on a low-disorder host material, enabling automated probing of single electrons in spin qubit arrays across...

HL-LHC’s Cold Powering System Successfully Passed Tests

If you’re an avid follower of High-Luminosity LHC (HL-LHC) news, you will no doubt already have heard about “the python”, the new superconducting link developed at CERN. It is a component of the new cold powering system that will power the HL-LHC inner triplet magnets, which will focus proton beams more...

Why We Still Need a CERN for Climate Change

It was a scorcher last year. Land and sea temperatures were up to 0.2 °C higher every single month in the second half of 2023, with these warm anomalies continuing into 2024. We know the world is warming, but the sudden heat spike had not been predicted. As NASA climate...

New Guide Published: “Select Thermal Properties for Cryogenic Insulation Materials”

Korean Register has published the “Guide to Selection of Thermal Properties of Cryogenic Insulation Materials” for safe storage of cryogenic fuels, including LNG and liquid hydrogen. Last year, the International Maritime Organization (IMO) adopted the ‘2023 Greenhouse Gas Strategy’ with the goal of achieving carbon neutrality in international shipping by 2050....

Cryogenics in Zero Gravity

As we plan for future interplanetary spaceflight, one major aspect remains untested: refueling in space. That’s because most rocket propellants are cryogenic liquids whose long-term behavior in space is still unknown. Purdue University researchers are collaborating with NASA to study cryogenic liquids in zero gravity, leading to the possibility of...

Modified Pulse Tube Refrigerator Halves Cryogenic Cooling Time

A simple modification to a popular type of cryogenic cooler could save $30 million in global electricity consumption and enough cooling water to fill 5000 Olympic swimming pools. That is the claim of researchers at the National Institute of Standards and Technology (NIST) and the University of Colorado Boulder who...

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Power usage: cryogenic systems vs. regular refrigerators

A recent project highlighted to me that closed cycle cryogenic cooling systems use far more electrical power to reduce temperatures by a few watts than regular refrigerators. I am sure it must be something to do with the extra difficulty of removing the heat from the liquid nitrogen or similar...

Redundancy strategies for mechanical -80C freezers

I was wondering what kind of redundancy strategies are people using for their mechanical -80C freezers? I am aware of the following. Please add if you are doing something different. 1) 1 Backup freezer for every 10 freezers – Empty and maintained at -80C at all times 2) Backup C02...

Method to move components in a cryogenic environment

Does anyone know of a method with which to reliably move components in a cryogenic environment? We are interested in moving detectors in a cryogenically cooled (2K) vacuum chamber, which is contained within a larger cryostat/isolation vacuum with thermal shields. As the desired horizontal or vertical displacement is between 10...