ADVERTISEMENT

Blood Banks: Cryogenic Blast Freezing to -90°C in Minutes Increases Throughput

Blood banks utilize freezers to rapidly freeze and store a range of thermally sensitive products such as blood plasma and cryoprecipitate. However, conventional compressor-based freezers can take hours to reach the ultra-low target temperature, slowing processing to a level that may not be sufficient for many operations. The challenge is...

Cryogenics Specialist Orders First Satellite for Detecting Methane Leaks

Absolut Group, a French cryogenic technology provider, said Dec. 7 it has ordered a demo nanosatellite for a constellation that would use sensors at very low temperatures to detect greenhouse gas leaks. The company’s newly created Absolut Sensing subsidiary ordered the chassis for a 16U satellite it calls Gen1 from Lithuania’s...

Got Propane?

As the maritime industry mulls the ‘fuel of the future,’ a strong and growing case can be made for propane based on availability, cost and ease of use compared to competitive fuels. Darren Monzingo, president of FARO Industrial and VP of Engineering for GEM Marine, is a marine engineer and naval...

Trenta’s Final Fusion Test Campaign

In 2023, Helion Energy, Inc., an American fusion research company, will end operations on Trenta, its 6th fusion prototype. The team is now undergoing Trenta’s last-ever fusion test campaign. For two years, its scientists and engineers have carried out rigorous research to test the capabilities of this fusion machine. The Helion...

Eta Space Commissions Liquid Hydrogen Test Facility

Eta Space is excited to announce the commissioning of a Liquid Hydrogen (LH2) Test Facility (LHTF) now available at their location in Rockledge, Florida. Customers can test their hardware and materials using LH2 with the benefit of small batch production. Previously only available in large quantities at high costs, Eta...

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Power usage: cryogenic systems vs. regular refrigerators

A recent project highlighted to me that closed cycle cryogenic cooling systems use far more electrical power to reduce temperatures by a few watts than regular refrigerators. I am sure it must be something to do with the extra difficulty of removing the heat from the liquid nitrogen or similar...

Redundancy strategies for mechanical -80C freezers

I was wondering what kind of redundancy strategies are people using for their mechanical -80C freezers? I am aware of the following. Please add if you are doing something different. 1) 1 Backup freezer for every 10 freezers – Empty and maintained at -80C at all times 2) Backup C02...

Method to move components in a cryogenic environment

Does anyone know of a method with which to reliably move components in a cryogenic environment? We are interested in moving detectors in a cryogenically cooled (2K) vacuum chamber, which is contained within a larger cryostat/isolation vacuum with thermal shields. As the desired horizontal or vertical displacement is between 10...