ADVERTISEMENT

SESAME Delivers Its First Light

Scientists at SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) recorded first monochromatic light through the XAFS/XRF spectroscopy beamline in November, signaling the start of the laboratory’s experimental program. The beamline, SESAME’s first to come on stream, delivers X-ray light that will be used to carry out...

FAST Electron Beam Achieves Milestone Energy

In November, a team at the Fermilab Accelerator Science and Technology (FAST) facility ramped up a beam of electrons to 300 million electronvolts, a double milestone event, according to the lab. For one, the beam surpassed the threshold needed to launch a new accelerator physics program at Fermi National Accelerator...

Argonne Welcomes GRETINA Back Home

A world-class gamma ray spectrometer called GRETINA has returned to Argonne National Laboratory (CSA CSM) for a second run expected to last 18 months. Scientists will use the instrument in conjunction with Argonne’s Fragment Mass Analyzer, where it will enable studies of nuclei at or near the proton drip line...

UTSW Releases First Atomic Structure From its Cryo-EM Facility

UT Southwestern Medical Center researchers have published a 3-D atomic structure of the ion channel found in mammals that is implicated in a rare, inherited neurodegenerative disease in humans. The work marks the first such structure determined using the university’s $17 million cryo-electron microscopy (cryo-EM) facility.

Novel Lenses Enable X-ray Microscopy with Record Resolution

Researchers at DESY have reported the creation of novel lenses that enable X-ray microscopy with record resolution. The new lenses consist of over 10,000 alternating layers of a new material combination—tungsten carbide and silicon carbide—that allowed the team to achieve a focus spot size with a diameter of less than...

ICC20 Accepting Abstracts for 2018 Conference

Abstract submission is now open for the 20th International Cryocooler Conference (ICC20), the premier global gathering on cryocooler technology. The meeting will feature oral and poster presentation sessions, plus CSA's Foundations of Cryocoolers short course.

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Sealant Adhesive KAE 89?

Can you give me contact details for the manufacturer of a “sealant Adhesive” KAE 89? It is a vapor stop, used on insulation covering LNG carrying conduits. This is a suggested alternative to Foster 90-66. Do you have details of any other alternative products for this application?