“Bad Metal” Reveals Clues to High-Temperature Superconductivity

A research collaboration based at Stony Brook University has found that “stripes” of electronic charge, which may play a key role in superconductivity, persist across surprisingly high temperatures, shape conductivity and have direction-dependent properties. The findings—published in Physical Review Letters—came as the group studied metals that conduct electricity poorly, looking...

NIST Hybrid Cooler Hits 2 Kelvin

NIST scientists have devised a novel hybrid system for cooling superconducting nanowire single-photon detectors (SNSPD). It uses a pulse-tube refrigerator cooled to 10 K to precool a Joule-Thomson cryocooler that can then reach 2 K. That level of cooling has typically been achieved with liquid helium systems that are costly,...

Beam Delivered to Muon g-2, First Results Expected Later this Year

Accelerators at the Fermi National Accelerator Laboratory (CSA CSM) have delivered beam to the Muon g-2 experiment for the first time, kicking off a three-year effort to measure what happens to those particles when placed in a precise magnetic field. The answer could rewrite scientists’ picture of the universe and...

NY Allocates $15 Million for Brookhaven Cryo-Electron Microscope

The Brookhaven National Laboratory has announced a $15 million allocation from New York State to fund a cryo-electron microscope at the Long Island Facility for Electron Microscopy, a new facility on its campus. The microscope will operate at 77 K and will provide researchers with a new look at molecular...

Sandwiched Graphene Adopts Andreev States

MIT physicists have found that a flake of graphene, when sandwiched between two superconducting materials, can inherit some of those materials’ superconducting qualities. The electronic state of the graphene changes dramatically here, even at its center, as the particles pair up in Andreev states—a fundamental electronic configuration that allows a...

Auguste and Taylor-Wharton Ink New Distribution Deal

Auguste Cryogenics has signed a long-term liquid cylinder distribution agreement with Taylor-Wharton, becoming the exclusive distributor in Europe, Russia and Israel for Taylor-Wharton’s extensive line of gas and liquid withdrawal cylinders.

ADVERTISEMENT

Dilution Refrigerators

Dilution refrigerators are a common technique for reaching temperatures below 1K, particularly where continuous cooling at these temperatures is required. Helium exists in two stable isotopes: 4He and 3He. Naturally occurring 3He is extremely rare, constituting less than 1 part per million of helium gas. However, 3He can be manufactured,...

Oxygen Deficiency Hazards

Oxygen Deficiency Hazards (ODH) are a significant safety issue in cryogenic facilities. ODH occurs when inert gases such as nitrogen, helium or argon displace room air and thus lower the percentage of oxygen in the space below that required for human life. OSHA defines an area as oxygen deficient if...

Kelvin Temperature Scale

The Kelvin temperature scale is the principal temperature scale used in cryogenics and science. The kelvin is also one of the seven base units in the Système International d’Unités (SI) and is the unit of thermodynamic temperature. Thermodynamic temperature is a fundamental physical quantity (like mass, length or electrical current)...

History of Cryogenics

From the Fall 1999 issue of Cold Facts magazine Millennium Breakthroughs A variety of CSA members give different perspectives on the past millennium: What were the most significant breakthroughs in cryogenics during the past millennium? Prof. R.G. Scurlock, Kryos Technology, scurlock@soton.ac.uk (“Breakthrough” = way through obstacles — Oxford English Dictionary)...

Cryobiology

Andreas Sputtek Past President Society for Cryobiology sputtek@uke.uni-hamburg.de or http://www.sputtek.de/. The word cryobiology (from the Greek words “cryo” = cold, “bios” = life, and “logos” = science) literally signifies the science of life at low temperatures. In practice, this field comprises the study of any biological material or system (e.g.,...

Cryogenic Insulation

James E. Fesmire Cryogenics Test Laboratory NASA Kennedy Space Center james.e.fesmire@nasa.gov Introduction In today’s world, the use of cryogenics and low-temperature refrigeration is taking a more and more significant role. From the food industry, transportation, energy, and medical applications to the Space Shuttle, cryogenic liquids must be stored, handled, and...

Cryogenic Treatment of Materials

F.J. Diekman Controlled Thermal Processing, Inc. info@metal-wear.com Cryogenic Processing (also called cryogenic treatment, and incorrectly “cryogenic tempering”) is a process that uses cryogenic temperatures to modify materials to enhance their performance. Cryogenic Processing involves the slow reduction in temperature of the material to at least -300°F (-185°C) and holding the...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...