After 50 Years of ASC and Magnet Conductors, What’s Next?

Past and present superconducting magnet technology suggests that cheap, strong, available-by-the-ton Nb-Ti alloy conductors will always be used unless it’s absolutely necessary to use another superconducting material. In this decade “absolutely necessary” has taken on a clearer definition, thanks to ITER, the upgrade of LHC, 1 GHz NMR magnets, the...

Laser Powered Cryocooling Drops to 91 K

Over the last couple of decades researchers around the world have been working on optical refrigeration, a new solid-state cooling scheme based on light-matter interactions, and a team of researchers from the University of New Mexico (UNM) and ThermoDynamic Films, LLC (TDF) is currently working to harness the physics of...

Testing JWST’s MIRI Cooler Compressor Assembly

The James Webb Space Telescope’s (JWST) Mid InfraRed Instrument (MIRI) cooler subsystem features a closed cycle helium Joule-Thomson (JT) cryocooler pre-cooled by a three-stage pulse tube cryocooler. In this paper, researchers from Northrop Grumman discuss tests conducted on the CCA, a flight model sub-assembly that compresses and precools MIRI's helium...

Cryogenic System to Cool Malaysian Data Center

An international consortium has announced plans to construct a green data center that features liquid submersion cooling at a location in Malaysia's Klang Valley. The project aims to increase the sustainability of data centers by changing the way facilities are cooled, therein reducing energy consumption by up to 50 percent,...

Fine-Tuned Cryogenic Clock Improves Computing Capabilities

Researchers from the University of Adelaide in South Australia have enhanced the cryogenic sapphire clock to achieve near attosecond capability. Also known as a microwave oscillator, the clock features a five cm cylinder-shaped crystal cooled to -269°C.

New Graphene Hybrid Exceeds DOE Goal for Hydrogen Storage

Layers of graphene separated by nanotube pillars of boron nitride may be a suitable material to store hydrogen fuel in cars, according to a new computational study from Rice University published in the journal Langmuir. The material held 14.77 percent of its weight in hydrogen at -321°F, exceeding both current...

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Wind Tunnels

Dr. Robert Kilgore The development of the cryogenic wind tunnel is one of many significant breakthroughs in both cryogenics and wind-tunnel technology made during the past millennium. Interest in the development of high-speed commercial and military aircraft resulted in a review of problems of flow simulation in transonic wind tunnels...

Suppliers of regenerator materials

I was looking for suppliers of regenerator materials. Can you please provide a list of vendors for: • Lead spheres • Bronze screen discs • Rare earth materials and spheres Thank you in advance for any help you can provide.

Containing ice accumulation while recovering helium

We are implementing a system to recover helium from our Janis ST-500 continuous flow LHe cryostat. The recovery system uses standard 1/4″ plastic tubing, which we connect directly to the cryostat’s exhaust port. The problem with this setup is that the gas is still quite cold as it leaves the...