ADVERTISEMENT

Experts Engineer New Cryostat Design Volume

The proper design of cryostats requires knowledge of many disciplines including: cryogenic properties of materials, heat transfer and thermal insulation, instrumentation, safety, structures and seals. One of the best ways to learn about cryostat design is to study the design choices and resulting performance of previous designs. This book provides...

Technifab Restructures, Announces Three Divisions

Technifab Products, Inc. (CSA CSM) has announced organizational changes, segmenting its business into three distinct divisions—Technifab Cryogenics, Technifab CNC Manufacturing and Technifab Cryodewars.

Density of Electron Pairs Key to Cuprate Superconductivity

Physicists at the US Department of Energy's (DOE) Brookhaven National Laboratory have determined a new reason for why cuprates become superconducting at high temperature. After growing and analyzing thousands of samples of a cuprate known as LSCO for the four elements it contains (lanthanum, strontium, copper and oxygen), the team...

Major Experiments Update Results at ICHEP2016

Researchers from several of the world's major institutions made announcements during the 38th International Conference on High Energy Physics, including physicists working at CERN, the T2K Collaboration and Fermi National Accelerator Laboratory (CSA CSM).

New Material Discovery Allows Study of Elusive Weyl Fermion

Researchers at the US Department of Energy's Ames Laboratory have discovered a new type of Weyl semimetal, a material that opens the way for further study of Weyl fermions, a type of massless elementary particle hypothesized by high-energy particle theory and potentially useful for creating high-speed electronic circuits and quantum...

Sting vs. MRI, Don’t Scan so Close to Me

Researchers at Canada's McGill University didn't turn on a red light, but managed nevertheless to lure musician Sting into a lab for an unusual neuroscience study based on his brain scans. The findings, published in the journal Neurocase, offer insights into how gifted individuals find connections between seemingly disparate thoughts...

ADVERTISEMENT

Refrigerators and Liquefiers

Two of the most common terms used in cryogenics are “refrigerator” and “liquefier.” These terms describe similar and, as will be seen, in some cases identical components. A refrigerator provides cooling (that is, absorbs heat) at cryogenic temperatures. Refrigerators typically put a working fluid (such as helium) through one of...

Air Separation

Air separation is one of the largest, as well as earliest, industrial applications of cryogenics. In this process, cryogenic temperatures are used to separate air into its constituent gases: nitrogen (78.08%), oxygen (20.95%), argon (0.93%) and carbon dioxide (0.3%). Trace gases such as krypton, neon, xenon and helium total far...

Coefficient of Performance and Figure of Merit

The coefficient of performance (COP) is used to describe the effectiveness of refrigerators, including those operating at cryogenic temperatures. The COP is defined as the amount of heat removed at the cryogenic operating temperature of the refrigerator divided by the amount of work that must be applied to remove the...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...