ADVERTISEMENT

Chicago Hosts World’s Largest High-Energy Physics Conference

More than 1,300 physicists from around the world will converge in Chicago for the biennial International Conference on High Energy Physics (ICHEP) in August to share new research results, announce new projects and talk about the most intriguing mysteries of the universe. The conference will meet August 3-10 at Chicago's...

Mayo’s New MRI is Compact, Comfortable and Powerful

Mayo Clinic has unveiled a new compact 3T magnetic resonance imaging (MRI) scanner designed specifically to handle scans of the head and small extremities—such as wrists, feet and ankles—that represent around 45 percent of the clinical MRI volume at the clinic.

New Cryo-Coil Improves MRI Performance

A research team has developed a high-temperature superconducting cryo-coil that allows magnetic resonance imaging (MRI) scanners to produce higher resolution images or acquire images in a shorter time than when using conventional coils. The cryo-coil works by boosting the signal-to-noise ratio (SNR)—a measure of the strength of signals carrying useful...

Scientists Map Structure of Virus Linked to Childhood Asthma

The atomic structure of an elusive cold virus linked to severe asthma and respiratory infections in children has been solved by a team of researchers at the University of Wisconsin-Madison and Purdue University. The virus was among the first samples analyzed with a new cryo-electron microscopy system at Purdue designed...

LUX Experiment Ends, Dark Matter Remains Elusive

Researchers from the Large Underground Xenon (LUX) dark matter experiment have confirmed that the experiment yielded no trace of dark matter during its final 20-month run (October 2014 - May 2016), even though its sensitivity far exceeded original expectations. The announcement was made during a presentation at the International Dark...

Physicists Collide Ultracold Atoms, Observe Pauli Exclusion

Physicists from New Zealand's University of Otago have used steerable 'optical tweezers' to split minute clouds of ultracold atoms and slowly smash them together to directly observe the Pauli Exclusion, a key theoretical principle of quantum mechanics.

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Seeking recommendations for commercial sensors

I would like to measure vibrations in small LHe cryostats. Could anybody recommend commercial sensors which would be suitable for the purpose? I am interested in the frequency range between 1Hz and a couple of KHz, with particular attention to the low frequency side.

Estimating cost of carbon steel, pure helium storage tanks

In order to perform an indicative cost assessment of our helium cryogenic plant (still in the design phase), I need an estimation of the cost of carbon steel room temperature pure helium storage tanks. The storage pressure is 20 bar. Can anyone give me suggestions about how to estimate the...

Supplier of pressure sensor that works down to 4.2 K

In an actual experiment we would like to measure the static pressure in a cryostat in the range between one and four bar. Therefore we are looking for some (more or less) cheap pressure sensors that work in liquid helium in the pressure range up to five bar. Unfortunately all...

Looking for reference/textbook suggestions

Can you suggest some reference textbooks for practical thermodynamics applications in cryogenic fields? I need textbooks with cryogenics calculations and examples, dimensioning procedures, second principle applications in cryogenics, heat load calculations, cryogenic pump application, etc. Do such books exist? Does any similar source of information exist?