ADVERTISEMENT

A Cryogenic Valve Primer

It is remarkable but true that we’ve used valves to control the flow of liquids for thousands of years. The city of Pompeii’s water system, for example, utilized quarter-turn style valves that were in principle very similar to those in use today. Cryogenic valves, while unique, are similar to these...

Air Liquide Designing Cryogenic System for ITER

Air Liquide has substantial expertise in designing, fabricating and installing large capacity gas liquefaction and refrigeration systems. Its engineers have completed major cryogenic installations, for example, at CERN and KSTAR (the South Korean Tokamak) and are now working on ITER, providing the project with a centralized helium cryogenic plant and...

Forget Nitro Brew Coffee, Meet Nitro Bean

The perfect roast for your next cup of joe might just come from liquid nitrogen chilled coffee beans. A team from the University of Bath, working with the Bath coffee shop Colonna & Smalls, reports that chilling roasted beans before grinding results in small uniform coffee grinds. This provides for...

NASA’s MIRI Cryocooler Passes Inspection, Set for Installation on Webb Telescope

Scientists at NASA's Jet Propulsion Laboratory (JPL) have completed testing of a first-of-its-kind cryocooler for NASA's James Webb Space Telescope. The cooler will chill one of the telescope's four instruments, the Mid-Infrared Instrument (MIRI), a device key to catching faint whispers of light from the very first stars born in...

LIGO Detects Gravitational Waves for a Second Time

Scientists from the LIGO Scientific Collaboration have observed gravitational waves for a second time, according to an announcement made on June 15 during the 228th meeting of the American Astronomical Society in San Diego. The detection of the waves—ripples in the fabric of spacetime—was made on Dec. 25 by both...

EMIR Spectrograph Installed on Gran Telescopio CANARIAS

Engineers at the Roque de los Muchachos Observatory have attached the EMIR spectrograph to the Gran Telescopio CANARIAS (GTC), realizing a more than decade long design and fabrication process. The cryogenic instrument was designed, built, assembled and verified entirely at the IAC (Astrophysics Institute of Canrias). It will produce images...

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...