ADVERTISEMENT

Will Ultralow Temperatures Leave the Research Laboratory?

Dr. Joel Ullom, NIST, writes in his guest column: "Cryogenic techniques are widely used in industry and medical imaging. However, cooling to temperatures near 1K and below (into the millikelvin range) remains rare. Such ultralow temperatures (ULTs) are largely confined to research laboratories where they are a powerful tool for...

The Next Niobium Goal: Medium-Field SRF Cavities with High Quality Factor

In his guest column, Dr. Lance Cooley writes, "We are now beginning to evolve our present knowledge about producing high-gradient cavities to take on goals of high-Q CW cavities. The starting point for this transition is clearly to explore simple adaptations of the present ILC process. But it is not...

American College of Cryosurgery Holds Annual Meeting

The American College of Cryosurgery, founded in 1977, hosted its first meeting January 2-7, 2013, after a hiatus of nearly ten years. The meeting venues provided a unique experience for participants and accompanying guests. A land-based session was held at the Hyatt Regency Downtown Miami Hotel.

Donnelly Team Designs Cryogenic Remediation of Power Pollutants

Professor John M. Pfotenhauer writes, "The fields of low temperature physics and energy and environment do not frequently interact. Imagine my astonishment to find in the 2010 spring edition of a newsletter from the Department of Physics at my graduate school, the University of Oregon, that my thesis advisor from...

Cryo Community Mourns Donna Jung, International Cryogenics

It is with great regret that we report the sudden death of Donna Jung, President of International Cryogenics, on February 1, 2013. Jung was a leader in the cryogenic community, president of a longtime CSA Corporate Sustaining Member company, and a stalwart supporter of the Society. Jung, 52, was one...

ADVERTISEMENT

Stability

Stability refers to the ability of a device employing superconductors to remain in its superconducting state after part of the superconductor transitions back to its normal conducting state due to a disturbance. While the concept can apply to many superconducting devices—transmission lines, generators, motors, etc.—it is most commonly considered in...

Cable-in-Conduit Conductors

Cable-in-Conduit Conductors (CICC) are a common form of superconducting cable used in large-scale applications. There are several varieties of CICCs, but they all consist of many small, stabilized superconducting wires contained within a conduit through which a coolant (typically supercritical He II) flows. Figure 1 shows the cross section of...

Bayonet Coupling

A bayonet coupling is a demountable joint that allows for quick and easy connection and disconnection of cryogenic components, including transfer lines, cryostats, liquefiers and refrigerators. Bayonets provide a number of advantages, chief among them the ability to connect and disconnect the bayonets while components they connect are still at...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...