ADVERTISEMENT

High-Resolution Cryo-EM Starts Focusing on Accessibility

Structure-based designs are integral to advancing drug discovery, and in this regard, cryogenic electron microscopy (cryo-EM) has emerged as a pivotal tool for achieving high-resolution structures of proteins and protein complexes. Particularly noteworthy is its utility in elucidating the structures of protein classes that have historically resisted crystallization. Cryo-EM’s pivotal...

Cryogenic Etch Re-Emerges

Cryogenic etch, sometimes called cryo etch, is one of two ways to enable deep silicon or high-aspect ratio (HAR) etches in devices, where the features are long, narrow and deep. The other and most popular method is the two-step Bosch process, where you etch out a part of the structure...

RegO Adds Pressure Regulators for Cryogenic Vessels

RegO Products has unveiled its latest breakthrough: the CBE504 Series of Half-Inch Pressure Builder-Economizer Regulators. Designed to enhance cryogenic vessel operations, these regulators prioritize pressure control and product preservation. The CBE504 Series boasts numerous improvements over the previous CB504 model, including a more compact form factor and a broader range...

Tokamak Energy’s Fusion Magnet System Passes Cryogenic Tests

UK-based Tokamak Energy’s superconducting magnet system, which is being built to replicate fusion energy power plant forces, has passed significant milestone cryogenic tests. Creating fusion energy requires strong magnetic fields to confine and control the extremely hot hydrogen fuel, which becomes a plasma several times hotter than the center of...

Ziath Preserves the Future, One Sample at a Time

In the realm of scientific discovery, the value of biological specimens cannot be overstated. They serve as essential windows into understanding life’s intricate mysteries. From the smallest molecules to the most complex organisms, researchers strive to unlock the secrets held within these samples. To safeguard these invaluable assets, a pioneering...

ADVERTISEMENT

Two-Phase Flows

Two-phase flows are those flows in which there is a mixture of two physical states (solid, liquid or vapor). In cryogenic applications, such flows are almost always a mixture of a cryogenic liquid along with its corresponding vapor. A mixture of liquid helium and helium vapor would be a typical...

Supercritical Fluids

A supercritical fluid is defined as a substance whose temperature and pressure exceed those of its critical point. Every pure substance has a critical point that is defined in thermodynamic space by a critical temperature and a corresponding critical pressure. For example, the critical point for helium has a critical...

Brayton Cycle

The Brayton cycle is one of the many thermodynamic cycles used to generate cooling at cryogenic temperatures. Strictly speaking, when referring to cooling we should call this the reverse Brayton cycle as the original Brayton cycle describes the process of power generation or propulsion via a gas turbine. In many...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...