ADVERTISEMENT

International Cryogenic Research, Industry Leaders Meet for Virtual CEC-ICMC ’21

While the pandemic may have changed the approach, organizers and attendees of the 2021 Cryogenic Engineering Conference–International Cryogenic Materials Conference participated in a valuable week of presentations, discussions, posters, short courses and exhibitions. Held virtually via Whova® from July 17–23, CEC-ICMC hosted over 670 attendees from across the globe in...

Leading Xenon Researchers Unite to Build Next-Generation Dark Matter Detector

The DARWIN and LUX-ZEPLIN collaborations have now joined forces to work together on the design, construction and operation of a new, single, multi-tonne scale xenon observatory to explore dark matter. The announcement was made July 20. The detector will be highly sensitive to a wide range of proposed dark matter...

Cryotherapy System Treats Superficial Bladder Cancer

A minimally invasive cryoablation system offers a novel approach for the treatment of non muscle invasive bladder cancer (NMIBC). The Vessi Medical minimally invasive cryotherapy solution is designed to provide a bladder-specific system that reduces the cost and eliminates complications associated with the current first-line treatment, transurethral resection of bladder...

Supersolidity Enters a Second Dimension

Atoms in a Bose-Einstein condensate (BEC) can exist in a mysterious “supersolid” state in two dimensions, researchers in Austria have shown. The work, which builds on research from 2019 demonstrating supersolidity in one dimension, opens the way to hitherto impossible tests of theoretical predictions about this long-unexplained phenomenon.

How The Ford Motor Company Invented the SQUID

Cooled to a few degrees above absolute zero, a superconducting quantum interference device, or SQUID, can do something amazing: detect a magnetic field only a millionth as strong as the human brain’s, or less than 5 quintillionths of a tesla.

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...