ADVERTISEMENT

SpaceX Conducts Cryogenic Test on Starship SN15

On April 13, Starship SN15 went through the cryogenic proof test. The cryo-test ensures if a spaceship is able to withstand in-flight atmospheric pressures and extremely low temperatures. This is achieved by simulating the in-flight conditions by filling the Starship with liquid nitrogen that has a temperature of −196 °C...

Researchers Develop Cryogenic Coffee Grinding Technology

Skoltech Ph.D. Dima Smirnov and his colleagues from St. Petersburg, Alexander Saichenko, Vladimir Dvortsov, Mikhail Tkachenko and Maxim Kukolev developed a cryogenic cooling technology and combined it with a cryogenic grinding technique to produce, for the first time ever, retail cryoground coffee.

Honoring the Hugets

After 42 years of continued leadership and direction, Laurie and Werner Huget have retired from CSA. For decades, the Hugets have overseen CSA’s day-to-day operations, organized conferences and workshops attended by professionals from around the world and facilitated countless short courses for the cryogenics community. We invite you to continue...

JanisULT, Formerly Janis Research, Launches New Website

In August 2020, Janis Research Company, LLC (CSA CSM) announced a formal change in company name to JanisULT (a trading name of American ULT Cryogenics, LLC) following the successful sale of their laboratory cryogenics business to Lake Shore Cryotronics (CSA CSM). On March 12, the company announced their updated website,...

IceCube Detection of a High Energy Particle Proves 60-Year-Old Theory

On December 6, 2016, a high energy particle called an electron antineutrino hurtled to Earth from outer space at close to the speed of light carrying 6.3 petaelectronvolts of energy. Deep inside the ice sheet at the South Pole, it smashed into an electron and produced a particle that quickly...

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

In search of a calculation for designing a cryostat

I am a final year physics student at the University of Birmingham, and as part of a group I am currently designing a cryostat. One of the calculations I need to make (very soon!) is how much heat will be conducted down the walls. All information I have found so...

Safety of ethylene glycol and pressurized oxygen

We are reviewing the product design of liquid filled differential level gauges and want to insure that they meet the industry requirements. The former license owner had authorized that a fill fluid of ethylene glycol (68%) and distilled water (32%) could be used for oxygen service up to 500 psi....