With the power of Proton Improvement Plan-II, Fermi National Accelerator Laboratory is planning to construct and operate the foremost facility in the world for particle physics utilizing intense beams.
Pumps and their efficiencies will increase the heat load of a closed loop cryogenic cooling system, so it is important that these pumps be as efficient as possible to minimize cost and supply use. Francesco Dioguardi, Martijn Donkers and Harrie Vermeulen of DH Industries provide pump design and operation tips...
Dr. Danko van der Laan, the 2014 Roger W. Boom awardee, discusses the development of high temperature superconductors (HTS) and their applications in high field magnets and advanced power transmission. He also explains an approach to cable ReBCO tapes called Conductor on Round Core (CORC™) cables, which feature layers of...
Nature reports that scientists in Germany have observed the common molecule hydrogen sulfide superconducting at a record-breaking 203K (-70°C) when subjected to very high pressures. Researchers A. P. Drozdov, M. I. Eremets, I. A. Troyan, V. Ksenofontov and S. I. Shylin report their findings in their paper "Conventional superconductivity at...
The Japan Society of Applied Physics (JSAP) has published the first issue of the new JSAP Bulletin, a tri-annual online publication designed to highlight JSAP's activities and inspire a global audience engaged in academic and industrial research.
After five months of repairing and retooling the Booster Neutrino Beamline (BNB), members of the Accelerator Division at Fermi National Accelerator Laboratory successfully delivered beam to the BNB on June 22. The previous horn, BNB-2, was found to be inoperable in January when it was determined its cooling was no...
Most cryogenic refrigeration systems, both large scale systems and cryocoolers, use helium as a working fluid. There are a number of advantages to helium, not the least of which is that helium remains a fluid down to the lowest achievable temperatures. In order to freeze helium, pressures of over 20...
Helium II (He II), the second liquid phase of the 4He isotope described in this column in Cold Facts Spring 2010 (http://2csa.us/he2), can be modeled as consisting of two interpenetrating fluids. One, the superfluid component, has zero viscosity and entropy and the other, the normal fluid component, has nonzero viscosity...
A vital technology in the refrigerators and liquefiers described in Cold Facts Volume 31 Number 3 is that of turboexpanders. These devices are rotating machines in which the process fluid (e.g., helium) does work against the turboexpander while moving from high pressure to a lower pressure and thus is cooled....
by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...
A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...
While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...
The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...
Currently we use in our Biobank an upright -80 freezer to store all our samples. We are planning to buy a fully automated bio-repository storage that will do the picking of samples under restricted conditions. But in the meantime I foresee that we have to pick the samples manually. The...
I am looking into standardizing our range of bio storage tubes (cryogenic vials). These will be for both blood and tissue samples and their derivatives. Any recommendations, comments on Micronics, Nalgene, Nunc and or others that are suitable for long term -80 C and -196 C storage, DNA/RNA suitable, would...
We are an ice making company and have started a new project, which is related to flash freezing of water. It is based on cryogenics technology and we need a custom made machine. I would kindly ask you to pass me a few companies who would be interested in such...
I would like to construct a small cooling circuit (appr. 50 x 50 cm) pumping liquid at a temperature down to -120°C from a cold reservoir to the specimen to be cooled. The tubes and connections are not a problem, but does somebody know a pump (suction/compression for circulation) suitable...