Frederick J. Edeskuty, 89, long-time CSA member, Cold Facts columnist and expert on cryogenic safety, passed away on Friday, May 10. After receiving his doctoral degree in chemical engineering and physics at the University of Minnesota, he moved his family to New Mexico where he began a 40-year scientific career...
The US Department of Energy has conditionally authorized Freeport LNG Expansion, and FLNG Liquefaction, LLC (Freeport) to export domestically produced liquefied natural gas (LNG) to countries that do not have a Free Trade Agreement (FTA) with the United States from the Freeport LNG Terminal on Quintana Island, Texas.
Scientists from 26 institutions around the world are planning a new experiment that could open the doors to new realms of particle physics. But first, they have to bring the core of this experiment, a complex electromagnet that spans 50 feet in diameter, from the US Department of Energy's Brookhaven...
RI Research Instruments GmbH, a majority-owned subsidiary of Bruker Energy & Supercon Technologies, Inc. (BEST), announced the award of a contract for five radio frequency (rf) cavities for the Facility for Antiproton and Ion Research (FAIR) project, valued at approximately $5.8 million.
IceCure Medical reports that Dr. Eisuke Fukuma has treated 58 breast cancer patients with cryoablation over the last six years under a research protocol at Kameda Medical Center in Japan. As of now, they say, none of the patients have had a tumor reoccur or distant metastases. By choosing this...
Dilution refrigerators are a common technique for reaching temperatures below 1K, particularly where continuous cooling at these temperatures is required. Helium exists in two stable isotopes: 4He and 3He. Naturally occurring 3He is extremely rare, constituting less than 1 part per million of helium gas. However, 3He can be manufactured,...
Oxygen Deficiency Hazards (ODH) are a significant safety issue in cryogenic facilities. ODH occurs when inert gases such as nitrogen, helium or argon displace room air and thus lower the percentage of oxygen in the space below that required for human life. OSHA defines an area as oxygen deficient if...
The Kelvin temperature scale is the principal temperature scale used in cryogenics and science. The kelvin is also one of the seven base units in the Système International d’Unités (SI) and is the unit of thermodynamic temperature. Thermodynamic temperature is a fundamental physical quantity (like mass, length or electrical current)...
by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...
A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...
While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...
The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...
I would like to measure vibrations in small LHe cryostats. Could anybody recommend commercial sensors which would be suitable for the purpose? I am interested in the frequency range between 1Hz and a couple of KHz, with particular attention to the low frequency side.
In order to perform an indicative cost assessment of our helium cryogenic plant (still in the design phase), I need an estimation of the cost of carbon steel room temperature pure helium storage tanks. The storage pressure is 20 bar. Can anyone give me suggestions about how to estimate the...
In an actual experiment we would like to measure the static pressure in a cryostat in the range between one and four bar. Therefore we are looking for some (more or less) cheap pressure sensors that work in liquid helium in the pressure range up to five bar. Unfortunately all...
Can you suggest some reference textbooks for practical thermodynamics applications in cryogenic fields? I need textbooks with cryogenics calculations and examples, dimensioning procedures, second principle applications in cryogenics, heat load calculations, cryogenic pump application, etc. Do such books exist? Does any similar source of information exist?