ITER’s Magnets Conquer the 4 K Cryostat Challenge

Embarking on the frontiers of innovation, ITER, the International Thermonuclear Experimental Reactor, heralds a new era with its superconducting magnets—a groundbreaking technological marvel designed to operate at an astonishingly low temperature of 4 K (-269 °C), just above absolute zero. ITER’s primary purpose is to explore and demonstrate the potential...

Oxford Cryosystems’ Evolution From Lab to Global Innovation Hub

In the 1980s, John Cosier and Professor Mike Glazier from Oxford University pioneered the creation of an open-flow cooler, initially designed for exclusive use in Oxford University’s Clarendon Laboratory. Its remarkable efficiency quickly gained recognition within the crystallographic community, leading researchers worldwide to seek similar systems. Responding to this demand,...

RIX Liquid Oxygen Generation Plant Supports US Navy’s Newest Aircraft Carriers

Aircraft carriers use highly concentrated gaseous and liquid oxygen for aviation and medical applications. These legacy systems consume large amounts of valuable ship space and require constant attention and adjustment to meet purity and production rates. With the development of USS Gerald R. Ford (CVN-78) – the “first-in-class” nuclear-powered aircraft...

How Lake Shore Cryotronics is Helping Reduce Helium Costs in The Lab

Lake Shore Cryotronics’ Director of Product Management for Cryogenic Systems Rachael Floyd shares how Lake Shore Cryotronics is helping reduce helium costs in the lab. Why is the availability of helium becoming a pressing concern for research labs, and what unique challenges does it pose? The high cost of helium is a big...

New Glenn Completes Initial Cryogenic Testing at Launch Complex 36

Blue Origin continues to take big steps forward with its New Glenn orbital rocket as hardware rolls out to the launch pad, cryogenic testing begins, and the BE-4 engine gains a new test stand. The company still aims to launch New Glenn at least once in 2024.  Over the past month,...

ADVERTISEMENT

Transfer Lines

Transfer lines may in some real sense be thought of as the cryogenic fluid analogy of current leads. While current leads carry electrical power to where it’s required in a cryogenic system, transfer lines do the same with cryogenic fluids. Transfer lines range in complexity from very simple U-tubes containing...

Zero Boiloff

Zero Boil Off cryostats are those that contain liquid cryogens but are designed to eliminate or vastly reduce the boil off of  the liquid. These cryostats combine some of the advantages of Cryogen-Free systems (e.g. ease of use and long operational lifetime) with the advantages associated with a reservoir of liquid...

Cryomodule

Cryomodule is a term that is most commonly used to refer to cryostats that contain superconducting radio frequency (SRF) cavities. Such cavities are used to accelerate charged particle beams and are a major component of modern particle accelerators. Using the term cryomodule to refer to cryostats containing SRF cavities appears...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

Assistance with resolving a sealing problem?

We are fabricating piping components for refrigeration service. These components must be leak checked at 15 bar (218 psig). We are using a gas test media that is 25% helium and experiencing difficulty on maintaining a seal on the flanged connections. Do you know anyone or any references that could...

Cryogenic data on leather and nomex

Could anyone please help me out with the following cryogenics data: Leather — mechanical properties at 77 K or lower Nomex — thermal conductivity @ 4 to 50 K I lost the data I had some time ago and although this should be easily accessible, I can’t find any reference...