ADVERTISEMENT

Report on World Congress of the ISC

The 17th World Congress of the International Society of Cryosurgery was held in Bali, Indonesia, last December. At the opening ceremony, Prof. Dr. Akmal Taher, Sp.U(K), Director General of the Ministry of Health of the Republic of Indonesia, welcomed the delegates. A total of 109 delegates from four continents attended...

16th Intl. Conference on RF Superconductivity held in Paris

Ah, Paris! The City of Lights was the setting for the SRF 2013 conference, held Sept. 22-27. The conference was the latest continuation of a series started in 1980 at Karlsruhe as a small workshop, and has grown to 412 attendees, featuring an exhibition with 20 industrial exhibitors, and offering...

Education in Cryogenics, Superconductivity: Some Updates 

The following are some recent updates and additions to the information offered at CSA’s website about educational opportunities in cryogenics and superconductivity, both in classrooms and nontraditional settings, in the US and around the world.

Registration Open for ‘Foundations of Cryocoolers’ Short Course at ICC18

Registration is now open for the “Foundations of Cryocoolers” short course to be held on Monday, June 9, 2014, right before the 18th International Cryocoolers Conference (ICC18). The conference will be held June 9-12 at Syracuse University, Syracuse NY. Conference Chairman is Rich Dausman of Cryomech, Inc. and Co-Chair is...

US Gov’t Shutdown Affects Cryo, Superconductivity

In October, it would have been hard to miss the news of the 16-day US federal government shutdown, even for those located outside of the United States. The shutdown came as a result of Congress’ inability to enact legislation appropriating funds for fiscal year 2014 or to agree on a...

ADVERTISEMENT

Stability

Stability refers to the ability of a device employing superconductors to remain in its superconducting state after part of the superconductor transitions back to its normal conducting state due to a disturbance. While the concept can apply to many superconducting devices—transmission lines, generators, motors, etc.—it is most commonly considered in...

Cable-in-Conduit Conductors

Cable-in-Conduit Conductors (CICC) are a common form of superconducting cable used in large-scale applications. There are several varieties of CICCs, but they all consist of many small, stabilized superconducting wires contained within a conduit through which a coolant (typically supercritical He II) flows. Figure 1 shows the cross section of...

Bayonet Coupling

A bayonet coupling is a demountable joint that allows for quick and easy connection and disconnection of cryogenic components, including transfer lines, cryostats, liquefiers and refrigerators. Bayonets provide a number of advantages, chief among them the ability to connect and disconnect the bayonets while components they connect are still at...

Air Separation and Liquefaction

by Nils Tellier, PE, President, EPSIM Corporation (CSA CSM) nils@epsim.us All illustrations courtesy EPSIM Corporation Background History of Air Separation and Liquefaction This section builds on a rich history of methods to develop deep refrigeration and cryogenic liquefaction during the 19th Century. You are encouraged to read Cryo Central’s History...

Bose-Einstein Condensate

A Bose-Einstein condensate, first proposed in 1925 by Albert Einstein based on work done by Satyendra Nath Bose (the same Bose from whom the term boson is derived), is a super-cold state of matter in which almost all of the individual atoms have “condensed” down to the lowest possible quantum...

Cold Technology for Pest Control

While it does not reach temperatures cold enough to be called cryogenic, carbon dioxide snow is at the heart of a new way of dealing with unwanted pests. It utilizes a quick freezing process that takes advantage of the properties of carbon dioxide snow and has a number of benefits...

Cryogenic Finishing

The following 3 articles discuss the uses and procedures of various type of cryogenic finishing. 1) By Robin A. Rhodes, Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Cryogenic Deflashing is employed to remove undesired residual mold flash that remains on molded parts after they are removed or ejected from the...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...