ADVERTISEMENT

In Memoriam: Dr. Roger W. Boom

It is with great regret that we report the death of Dr. Roger W. Boom, emeritus professor from the University of Wisconsin and mentor and inspiration to a great many leaders in the fields of cryogenic engineering and superconductivity. Dr. Boom’s career spanned more than thirty years during which he...

New Study Calls for US-based Electron Ion Collider

A new report, sponsored by the DOE and undertaken by the National Academies of Sciences, Engineering and Medicine, argues that a domestic electron ion collider could unlock the scientific mysteries of atomic nuclei and maintain US leadership in accelerator science.

Hawaiian Researchers Choose Cryogen-free MRI to Study Kidney Disease

MR Solutions has installed a cryocooler-based, and thus cryogen-free, preclinical MRI imaging system at the University of Hawaii to help researchers improve the rate of kidney disease detection. One in seven residents on the island has chronic kidney disease, a figure far higher than normal among its residents of Japanese,...

Health Officials in NY County Ban Liquid Nitrogen Treats

The Clinton County Board of Health has banned the sale of food products adulterated by liquid nitrogen. The move followed a study of Dragon's Breath, a dessert composed of cereal puffs frozen with liquid nitrogen, discussed on a New York State Association of County Health Officials conference call.

The Rise and Rise of Cryogenic Electron Microscopy

Speaking at the 68th Lindau Nobel Laureate meeting in Germany, biophysicist Joachim Frank says that the field of structural biology is entering a new era with a bright future thanks to advances in cryogenic electron microscopy. Cryo-EM rapidly freezes molecular samples in solution and images them with an electron beam...

ADVERTISEMENT

Adiabatic Demagnetization Refrigeration

Reaching temperatures below 1K requires different techniques than the various helium gas cycles found in large scale refrigeration plants and small cryocoolers. One of these techniques is Adiabatic Demagnetization Refrigeration (ADR). This technique takes advantage of the fact that the entropy of paramagnetic materials in a magnetic field is lower than...

Cryogen-Free

A cryogen is any fluid that operates at cryogenic temperatures (below roughly 150K – 120K). Using this definition, helium gas at 40K is a cryogen. Another more restrictive definition is to use cryogen to refer specifically to liquids at cryogenic temperatures. This is generally how it is used in the...

Cryostats and Cryocoolers

A cryostat is any device designed to maintain things (including fluids) at cryogenic temperatures. In general usage, cryostats tend to be passive devices rather than providing active cooling. In this usage, cryostats keep things cold by thermally isolating them from room temperature. This generally is accomplished by a combination of...

Food Processing

Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...