ADVERTISEMENT

Superconducting Magnet Sets 32-T World Record

The National High Magnetic Field Laboratory (CSA CSM) chalked up another world record in December when a new superconducting magnet at the facility reached a magnetic field of 32 teslas, a third stronger than the previous record and more than 3,000 times stronger than a common refrigerator magnet.

Friction Found in Superfluid Helium near Absolute Zero

Friction shouldn't appear in superfluid helium at temperatures near absolute zero, but that's just what researchers at Aalto University in Finland report observing in a new experiment. Understanding the causes and effects of the friction could pave the way for explorations into the composition of neutron stars and our universe,...

Brookhaven Brings a Hidden Superconducting State to Light

A team of scientists has detected a hidden state of electronic order in a layered material containing lanthanum, barium, copper and oxygen (LBCO). When cooled to a certain temperature and with certain concentrations of barium, LBCO is known to conduct electricity without resistance, but now there is evidence that a...

ADVERTISEMENT

Dilution Refrigerators

Dilution refrigerators are a common technique for reaching temperatures below 1K, particularly where continuous cooling at these temperatures is required. Helium exists in two stable isotopes: 4He and 3He. Naturally occurring 3He is extremely rare, constituting less than 1 part per million of helium gas. However, 3He can be manufactured,...

Oxygen Deficiency Hazards

Oxygen Deficiency Hazards (ODH) are a significant safety issue in cryogenic facilities. ODH occurs when inert gases such as nitrogen, helium or argon displace room air and thus lower the percentage of oxygen in the space below that required for human life. OSHA defines an area as oxygen deficient if...

Kelvin Temperature Scale

The Kelvin temperature scale is the principal temperature scale used in cryogenics and science. The kelvin is also one of the seven base units in the Système International d’Unités (SI) and is the unit of thermodynamic temperature. Thermodynamic temperature is a fundamental physical quantity (like mass, length or electrical current)...

Cryogenic Electronics

Randall Kirschman, consulting physicist, Mountain View, California ExtElect@gmail.com Cryogenic electronics—the operation of electronic devices, circuits, and systems at cryogenic temperatures—has been a valuable technology for decades. Cryogenic electronics (also referred to as low-temperature electronics, or cold electronics) can be based on semiconductive devices, on superconductive devices, or on a combination...

Particle Physics: High Energy Physics

Cryogenics and High-Energy Physics 1. From symmetry magazine: http://www.symmetrymagazine.org/cms/?pid=1000627: Cryogenics is the study of how materials behave at temperatures near absolute zero. In high-energy particle accelerators, such frigid temperatures reduce the electrical resistance of wires in superconducting magnets, increasing the magnet strength and allowing faster particle acceleration. The same holds...

HTS Degaussing Systems

From the Spring 2009 issue of Cold Facts (Volume 25, Number 2): Thanks to a joint project by the US Navy and a number of industry partners, high temperature superconducting (HTS) technology is now at the heart of an advanced degaussing system aboard the USS Higgins at the naval station...

Magnetic Resonance Imaging

From http://www.superconductors.org: An area where superconductors can perform a life-saving function is in the field of biomagnetism. Doctors need a non-invasive means of determining what’s going on inside the human body. By impinging a strong superconductor-derived magnetic field into the body, hydrogen atoms that exist in the body’s water and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...