ADVERTISEMENT

New test using cryogenic sapphire oscillators confirms speed of light

Researchers from the University of Western Australia and Humboldt University of Berlin used cryogenic temperatures to optimize frequency stability in a test designed to measure the spatial consistency of the speed of light with a precision ten times greater than ever before. The experiment compared the extremely pure microwave frequency...

Young Faces: The Next Generation in Cryogenics

We're pleased to present a new installment of Young Faces, a feature story we debuted in the Summer 2006 issue of Cold Facts introducing outstanding young professionals (under 40 years of age) who are doing interesting things in cryogenics and superconductivity and who show promise of making a difference in...

CSA Awards Presented at CEC/ICMC

John Weisend, CSA chairman, presented four awards at CEC/ICMC on July 1, including the first-ever William E. Gifford Award, given to a recipient in academia or at a government laboratory using a pulse tube or Gifford-McMahon cycle cryocooler as a key research component.

The 26th Space Cryogenics Workshop

This column presents a topical summary of the 2015 Space Cryogenics Workshop that was held June 24-26 in Phoenix AZ. The workshop was organized by David Plachta and Jason Hartwig of NASA/Glenn Research Center, and continued the tradition of bringing together specialists in the field of space cryogenics to discuss...

An Introduction to LNG as a Cryofuel

Technological advances in the US have unlocked massive quantities of natural gas, resulting in an abundant supply that should easily last many decades. This sustained situation has created two important consequences: the price of pipeline natural gas is low and stable, and, more significantly, the price of pipeline natural gas...

Improving the Efficiency of Helium Transfer Tubes

One must, on a daily basis, transfer liquefied gases, most notably helium from large static tanks or dewars to smaller transportable vessels. This process can become costly due to the losses sustained during transfer, which must be compensated for by reliquefying helium, requiring between 2 and 5 kW per liquid...

ADVERTISEMENT

Regenerators

Regenerators or regenerative heat exchangers are a key component of cryocoolers such as pulse tube cryocoolers (Cold Facts, August 2014). Regenerator performance greatly affects the coefficient of performance of cryocoolers. Improvements in regenerator design and, in particular, regenerator materials have been an important factor in the improvement of the performance...

Pulse Tube Cryocoolers

The development of pulse tube cryocoolers has been a significant topic of research and development over the past 20 or so years. Pulse tube cryocoolers have a number of advantages over other types of cryocoolers and are now available commercially. In order to understand pulse tube cryocoolers, it’s best to...

Thermal Expansion

Thermal expansion refers to the change in size (length or volume) that a material undergoes as its temperature changes. In cryogenic systems this effect can be quite large and must be allowed for in the design. In isotropic materials, which include most engineering materials, the thermal expansion is the same...

Cryogenic Electronics

Randall Kirschman, consulting physicist, Mountain View, California ExtElect@gmail.com Cryogenic electronics—the operation of electronic devices, circuits, and systems at cryogenic temperatures—has been a valuable technology for decades. Cryogenic electronics (also referred to as low-temperature electronics, or cold electronics) can be based on semiconductive devices, on superconductive devices, or on a combination...

Particle Physics: High Energy Physics

Cryogenics and High-Energy Physics 1. From symmetry magazine: http://www.symmetrymagazine.org/cms/?pid=1000627: Cryogenics is the study of how materials behave at temperatures near absolute zero. In high-energy particle accelerators, such frigid temperatures reduce the electrical resistance of wires in superconducting magnets, increasing the magnet strength and allowing faster particle acceleration. The same holds...

HTS Degaussing Systems

From the Spring 2009 issue of Cold Facts (Volume 25, Number 2): Thanks to a joint project by the US Navy and a number of industry partners, high temperature superconducting (HTS) technology is now at the heart of an advanced degaussing system aboard the USS Higgins at the naval station...

Magnetic Resonance Imaging

From http://www.superconductors.org: An area where superconductors can perform a life-saving function is in the field of biomagnetism. Doctors need a non-invasive means of determining what’s going on inside the human body. By impinging a strong superconductor-derived magnetic field into the body, hydrogen atoms that exist in the body’s water and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...