ADVERTISEMENT

Standards for cryogenic valves

Do you know where I can get some documents of testing specification or US standards for cryogenic valves (DN 250)? Or could you give me some suggestion for that?

Vendors for cryopreserved rat arteries

My department is starting up a microsurgery training lab as an adjunct to our resident curriculum. Instead of using live rats, we want to pursue the option of using cryopreserved rat arteries. I have been unsuccessful in finding animal/rodent vendors who deal in this. I basically found a lot of...

Source for pressure switch

Where can I find a pressure switch operating in the range 0.2 to 0.4 psi which is not affected by magnetic fields up to about 1000 Gauss?

Cryostat for storing fish samples at -20 degrees C

We are a small Food Chemistry Laboratory functioning within the Seychelles Bureau of Standards. We wish to purchase a cryostat for the purpose of storing fish samples at *-20ºC* prior to the analysis of Histamine in the tissue of Tuna by HPLC.

ADVERTISEMENT

Dewar

A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...

Stirling and Gifford-McMahon Cryocoolers

Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...

Liquefied Natural Gas (LNG)

A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...

Primary Standards

Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...

Shrink Fitting

Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...

Telecommunications

From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...

Wind Tunnels

Dr. Robert Kilgore The development of the cryogenic wind tunnel is one of many significant breakthroughs in both cryogenics and wind-tunnel technology made during the past millennium. Interest in the development of high-speed commercial and military aircraft resulted in a review of problems of flow simulation in transonic wind tunnels...

Sealant Adhesive KAE 89?

Can you give me contact details for the manufacturer of a “sealant Adhesive” KAE 89? It is a vapor stop, used on insulation covering LNG carrying conduits. This is a suggested alternative to Foster 90-66. Do you have details of any other alternative products for this application?