Standards for cryogenic valves
Do you know where I can get some documents of testing specification or US standards for cryogenic valves (DN 250)? Or could you give me some suggestion for that?
August 1, 2008
Recent material and fabrication developments in low-temperature regeneration
In the area of low-temperature regeneration, what are some recent material and fabrication developments?
August 1, 2008
Vendors for cryopreserved rat arteries
My department is starting up a microsurgery training lab as an adjunct to our resident curriculum. Instead of using live rats, we want to pursue the option of using cryopreserved rat arteries. I have been unsuccessful in finding animal/rodent vendors who deal in this. I basically found a lot of...
August 1, 2008
Source for pressure switch
Where can I find a pressure switch operating in the range 0.2 to 0.4 psi which is not affected by magnetic fields up to about 1000 Gauss?
August 1, 2008
Cryostat for storing fish samples at -20 degrees C
We are a small Food Chemistry Laboratory functioning within the Seychelles Bureau of Standards. We wish to purchase a cryostat for the purpose of storing fish samples at *-20ºC* prior to the analysis of Histamine in the tissue of Tuna by HPLC.
August 1, 2008
Dewar
A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...
June 18, 2018
Stirling and Gifford-McMahon Cryocoolers
Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...
May 2, 2018
Liquefied Natural Gas (LNG)
A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...
March 6, 2018
Cryogenic Electronics
Randall Kirschman, consulting physicist, Mountain View, California ExtElect@gmail.com Cryogenic electronics—the operation of electronic devices, circuits, and systems at cryogenic temperatures—has been a valuable technology for decades. Cryogenic electronics (also referred to as low-temperature electronics, or cold electronics) can be based on semiconductive devices, on superconductive devices, or on a combination...
November 5, 2009
Particle Physics: High Energy Physics
Cryogenics and High-Energy Physics 1. From symmetry magazine: http://www.symmetrymagazine.org/cms/?pid=1000627: Cryogenics is the study of how materials behave at temperatures near absolute zero. In high-energy particle accelerators, such frigid temperatures reduce the electrical resistance of wires in superconducting magnets, increasing the magnet strength and allowing faster particle acceleration. The same holds...
September 4, 2009
HTS Degaussing Systems
From the Spring 2009 issue of Cold Facts (Volume 25, Number 2): Thanks to a joint project by the US Navy and a number of industry partners, high temperature superconducting (HTS) technology is now at the heart of an advanced degaussing system aboard the USS Higgins at the naval station...
July 8, 2009
Magnetic Resonance Imaging
From http://www.superconductors.org: An area where superconductors can perform a life-saving function is in the field of biomagnetism. Doctors need a non-invasive means of determining what’s going on inside the human body. By impinging a strong superconductor-derived magnetic field into the body, hydrogen atoms that exist in the body’s water and...
July 8, 2009
Power usage: cryogenic systems vs. regular refrigerators
A recent project highlighted to me that closed cycle cryogenic cooling systems use far more electrical power to reduce temperatures by a few watts than regular refrigerators. I am sure it must be something to do with the extra difficulty of removing the heat from the liquid nitrogen or similar...
August 23, 2012
Redundancy strategies for mechanical -80C freezers
I was wondering what kind of redundancy strategies are people using for their mechanical -80C freezers? I am aware of the following. Please add if you are doing something different. 1) 1 Backup freezer for every 10 freezers – Empty and maintained at -80C at all times 2) Backup C02...
August 23, 2012
Safety guidelines for handling cryo vessels of nitrogen
I am looking for any safety guidelines for handling cryogenic vessels of nitrogen indoors and outdoors. I am especially interested in recommendations for area monitors to detect leaks, flow detection devices, etc.
August 23, 2012
Method to move components in a cryogenic environment
Does anyone know of a method with which to reliably move components in a cryogenic environment? We are interested in moving detectors in a cryogenically cooled (2K) vacuum chamber, which is contained within a larger cryostat/isolation vacuum with thermal shields. As the desired horizontal or vertical displacement is between 10...
August 23, 2012