Standards for cryogenic valves
Do you know where I can get some documents of testing specification or US standards for cryogenic valves (DN 250)? Or could you give me some suggestion for that?
August 1, 2008
Recent material and fabrication developments in low-temperature regeneration
In the area of low-temperature regeneration, what are some recent material and fabrication developments?
August 1, 2008
Vendors for cryopreserved rat arteries
My department is starting up a microsurgery training lab as an adjunct to our resident curriculum. Instead of using live rats, we want to pursue the option of using cryopreserved rat arteries. I have been unsuccessful in finding animal/rodent vendors who deal in this. I basically found a lot of...
August 1, 2008
Source for pressure switch
Where can I find a pressure switch operating in the range 0.2 to 0.4 psi which is not affected by magnetic fields up to about 1000 Gauss?
August 1, 2008
Cryostat for storing fish samples at -20 degrees C
We are a small Food Chemistry Laboratory functioning within the Seychelles Bureau of Standards. We wish to purchase a cryostat for the purpose of storing fish samples at *-20ºC* prior to the analysis of Histamine in the tissue of Tuna by HPLC.
August 1, 2008
Dewar
A dewar is a type of cryostat named after Sir James Dewar, the researcher who first developed the concept of a vacuum insulated container with silvered walls to reflect thermal radiation. Dewar was the first to liquefy hydrogen, and he created the device to store his discovery. The thermos bottle...
June 18, 2018
Stirling and Gifford-McMahon Cryocoolers
Stirling and Gifford-McMahon (GM) cryocoolers are two of the most commonly used cryocoolers in cryogenics. Both devices have a significant industrial base and operate at a wide range of temperatures and capacities. The thermodynamic cycles for both of these cryocoolers are quite similar. The Stirling cycle consists of a compressor,...
May 2, 2018
Liquefied Natural Gas (LNG)
A significant commercial application of cryogenics is the liquefaction, transport and storage of natural gas. Liquefied Natural Gas (LNG) is generally 95 percent methane with a few percent ethane and much lower concentrations of propane and butane. LNG liquefies at 111.6 K. Unlike many applications of cryogenics, the motivation for...
March 6, 2018
Food Processing
Cryogenics and Food The industrial gas industry provides a host of products and services related to food. The various gases have useful and sometimes fascinating applications in food industry. “The food industry is not a homogenous industry. The needs of customers processing hamburger vs. poultry vs. strawberries vs. seafood, for...
April 18, 2008
Primary Standards
Elie K. Track Hypres, Inc. elie@hypres.com http://www.hypres.com/ Primary standards involve the exact definition and realization of units of measurement for various quantities, time, length, mass, voltage, resistance, current, etc. International agreements based on the latest scientific knowledge define those units, and their realizations vary depending on the unit itself. For...
April 18, 2008
Shrink Fitting
Robin A. Rhodes Cryogenic Institute of New England, Inc. rrhodes@nitrofreeze.com Shrink fitting, (or “compression fitting” as it is sometimes called), is a method used to insert a pin or bushing into a housing or other assembly requiring an extremely tight tolerance fit. It can be used as an alternative to...
April 18, 2008
Telecommunications
From the Winter 2004 issue of Cold Facts magazine The recent M-Calc IV — 4th Industry Assessment workshop discussing military and commercial applications for low-cost cryocoolers, held in November in San Diego, highlighted progress being made in cryogenics as applied in telecommunications. The reliability and long lifetime of projects now...
April 18, 2008
Need help comparing chest freezers and upright freezers
Currently we use in our Biobank an upright -80 freezer to store all our samples. We are planning to buy a fully automated bio-repository storage that will do the picking of samples under restricted conditions. But in the meantime I foresee that we have to pick the samples manually. The...
August 22, 2012
Need recommendations for cryogenic vials
I am looking into standardizing our range of bio storage tubes (cryogenic vials). These will be for both blood and tissue samples and their derivatives. Any recommendations, comments on Micronics, Nalgene, Nunc and or others that are suitable for long term -80 C and -196 C storage, DNA/RNA suitable, would...
August 22, 2012
We need a custom machine for flash freezing of water
We are an ice making company and have started a new project, which is related to flash freezing of water. It is based on cryogenics technology and we need a custom made machine. I would kindly ask you to pass me a few companies who would be interested in such...
August 22, 2012
Looking for a pump suitable for cold liquids
I would like to construct a small cooling circuit (appr. 50 x 50 cm) pumping liquid at a temperature down to -120°C from a cold reservoir to the specimen to be cooled. The tubes and connections are not a problem, but does somebody know a pump (suction/compression for circulation) suitable...
August 22, 2012