Standards for cryogenic valves
Do you know where I can get some documents of testing specification or US standards for cryogenic valves (DN 250)? Or could you give me some suggestion for that?
August 1, 2008
Recent material and fabrication developments in low-temperature regeneration
In the area of low-temperature regeneration, what are some recent material and fabrication developments?
August 1, 2008
Vendors for cryopreserved rat arteries
My department is starting up a microsurgery training lab as an adjunct to our resident curriculum. Instead of using live rats, we want to pursue the option of using cryopreserved rat arteries. I have been unsuccessful in finding animal/rodent vendors who deal in this. I basically found a lot of...
August 1, 2008
Source for pressure switch
Where can I find a pressure switch operating in the range 0.2 to 0.4 psi which is not affected by magnetic fields up to about 1000 Gauss?
August 1, 2008
Cryostat for storing fish samples at -20 degrees C
We are a small Food Chemistry Laboratory functioning within the Seychelles Bureau of Standards. We wish to purchase a cryostat for the purpose of storing fish samples at *-20ºC* prior to the analysis of Histamine in the tissue of Tuna by HPLC.
August 1, 2008
Liquid Hydrogen
Hydrogen becomes a liquid at 20K and 1 bar. Liquid hydrogen (LH2) is an important substance in industry, transportation and research. Industrial uses of hydrogen include applications in the electronics, glass, chemical and metal processing fields. In these applications, the hydrogen is generally used as a room temperature gas but...
August 26, 2014
Superconducting Radiofrequency Cavities
Superconducting radio frequency (SRF) cavities represent an important application of cryogenics and superconductivity. SRF cavities are a technology for accelerating charged particle beams via the transfer of radiofrequency (RF) energy to the beams via resonant structures. As such, they are frequently found in large particle accelerators used for scientific research....
August 26, 2014
Thermal Radiation Shields
Actively cooled thermal radiation shields are a common feature of cryostats whose lowest temperature is less than 77K. These shields, which typically operate at temperatures between that of LN2 and 40K, block thermal radiation from higher temperatures from reaching lower temperature cryogenic components or fluids. Since the heat radiated from...
December 17, 2013
Cryogenic Electronics
Randall Kirschman, consulting physicist, Mountain View, California ExtElect@gmail.com Cryogenic electronics—the operation of electronic devices, circuits, and systems at cryogenic temperatures—has been a valuable technology for decades. Cryogenic electronics (also referred to as low-temperature electronics, or cold electronics) can be based on semiconductive devices, on superconductive devices, or on a combination...
November 5, 2009
Particle Physics: High Energy Physics
Cryogenics and High-Energy Physics 1. From symmetry magazine: http://www.symmetrymagazine.org/cms/?pid=1000627: Cryogenics is the study of how materials behave at temperatures near absolute zero. In high-energy particle accelerators, such frigid temperatures reduce the electrical resistance of wires in superconducting magnets, increasing the magnet strength and allowing faster particle acceleration. The same holds...
September 4, 2009
HTS Degaussing Systems
From the Spring 2009 issue of Cold Facts (Volume 25, Number 2): Thanks to a joint project by the US Navy and a number of industry partners, high temperature superconducting (HTS) technology is now at the heart of an advanced degaussing system aboard the USS Higgins at the naval station...
July 8, 2009
Magnetic Resonance Imaging
From http://www.superconductors.org: An area where superconductors can perform a life-saving function is in the field of biomagnetism. Doctors need a non-invasive means of determining what’s going on inside the human body. By impinging a strong superconductor-derived magnetic field into the body, hydrogen atoms that exist in the body’s water and...
July 8, 2009
An Issue of Pressure and Flow Rate in a Supply Tank
Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...
April 20, 2018
Using MLI on VJ Line Joints or Cryo Storage Tanks
When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...
April 20, 2018
Separated layers of ice over a pipe
I want to know that why there are different layers of ice over a pipe carrying a cryogenic fluid, each layer separated with clear marks / lines? What do these layers signify?
February 8, 2016
Using nitrogen as a cryogen
Is it possible to achieve -200˚C using nitrogen as a cryogen?
January 20, 2015





