ADVERTISEMENT

Dr. Joel Ullom receives CSA’s Roger W. Boom Award

Dr. Joel Ullom, 2012 CSA Roger W. Boom awardee, is the NIST Project Leader for superconducting calorimeter development and has worked in the fields of low temperature sensors, low temperature electronics and cryogenic systems since 1994.

Chemical synthesis achieves superconductivity at 44K

Physicists describe how they have synthesized a new material that belongs to the iron-selenide class of superconductors, called LixFe2Se2(NH3)y, in a paper about to be published in EPJ B. The work was carried out by Ernst-Wilhelm Scheidt from the University of Augsburg and colleagues.

CSA announces 2012 election results

CSA recently announced the results of the 2012 Board of Technical Directors election. The results were certified at CSA's board meeting at the Applied Superconductivity Conference in Portland OR.

ADVERTISEMENT

Two-Phase Flows

Two-phase flows are those flows in which there is a mixture of two physical states (solid, liquid or vapor). In cryogenic applications, such flows are almost always a mixture of a cryogenic liquid along with its corresponding vapor. A mixture of liquid helium and helium vapor would be a typical...

Supercritical Fluids

A supercritical fluid is defined as a substance whose temperature and pressure exceed those of its critical point. Every pure substance has a critical point that is defined in thermodynamic space by a critical temperature and a corresponding critical pressure. For example, the critical point for helium has a critical...

Brayton Cycle

The Brayton cycle is one of the many thermodynamic cycles used to generate cooling at cryogenic temperatures. Strictly speaking, when referring to cooling we should call this the reverse Brayton cycle as the original Brayton cycle describes the process of power generation or propulsion via a gas turbine. In many...

Cryogenic Electronics

Randall Kirschman, consulting physicist, Mountain View, California ExtElect@gmail.com Cryogenic electronics—the operation of electronic devices, circuits, and systems at cryogenic temperatures—has been a valuable technology for decades. Cryogenic electronics (also referred to as low-temperature electronics, or cold electronics) can be based on semiconductive devices, on superconductive devices, or on a combination...

Particle Physics: High Energy Physics

Cryogenics and High-Energy Physics 1. From symmetry magazine: http://www.symmetrymagazine.org/cms/?pid=1000627: Cryogenics is the study of how materials behave at temperatures near absolute zero. In high-energy particle accelerators, such frigid temperatures reduce the electrical resistance of wires in superconducting magnets, increasing the magnet strength and allowing faster particle acceleration. The same holds...

HTS Degaussing Systems

From the Spring 2009 issue of Cold Facts (Volume 25, Number 2): Thanks to a joint project by the US Navy and a number of industry partners, high temperature superconducting (HTS) technology is now at the heart of an advanced degaussing system aboard the USS Higgins at the naval station...

Magnetic Resonance Imaging

From http://www.superconductors.org: An area where superconductors can perform a life-saving function is in the field of biomagnetism. Doctors need a non-invasive means of determining what’s going on inside the human body. By impinging a strong superconductor-derived magnetic field into the body, hydrogen atoms that exist in the body’s water and...

An Issue of Pressure and Flow Rate in a Supply Tank

Please help solve this problem: A supply tank requires a vaporizer to generate sufficient pressure to pump stored fluid up into a vehicle or tank. The available head is limited as the tank level falls and it is important to minimize the system pressure drop to maintain the desired flow...

Using MLI on VJ Line Joints or Cryo Storage Tanks

When installing Multi Layer Insulation (MLI) blankets on VJ line joints or cryo storage tanks should they be wrapped and tied down tight or loose? These are usually pre-cut to size. Also should they have an access hole at the point of where the molecular sieve is installed to help...